    MicroCal PEAQ-ITC Automated
    Fully automated, hands free ITC for increased productivity



     

    The MicroCal PEAQ-ITC Automated is a configurable, low volume, highly sensitive isothermal titration calorimeter which offers the convenience of unattended operation. It delivers direct, label-free in solution measurement of all binding parameters in a single experiment. Applications include characterizing molecular interactions of small molecules, proteins, antibodies, nucleic acids, lipids and other biomolecules. It can also be used to measure enzyme kinetics

    Features and benefits

    The MicroCal PEAQ-ITC Automated combines the high sensitivity of the MicroCal PEAQ-ITC - the calorimeter core of the system - with walkaway automation, to meet the productivity needs of busy research and drug discovery laboratories. The system directly measures heat released or absorbed during biochemical binding events, from which it calculates binding affinity (KD), stoichiometry (n), enthalpy (ΔH), and entropy (ΔS). Other than preparing samples and reagents to appropriate concentrations, there is minimal assay development and time to first result is fast. Easy-to use software includes optimized automation scripts for robust operation with a variety of sample types and conditions.

    • User-friendly design tools assist in selecting experimental run parameters.
    • All binding parameters (affinity, stoichiometry, enthalpy and entropy) in a single experiment.
    • Quick to first result with minimal assay development, no labelling, no immobilization and no molecular weight limitations.
    • High signal to noise gives more confidence in accessing data quality and relevance of generated affinity and thermodynamic parameters.
    • Outstanding data quality for sub-millimolar to picomolar disassociation constants (10-2 to 10-12 M).
    • Coin shaped cell optimizes sample mixing.
    • Nonreactive Hastelloy for chemical resistance and compatibility with biological samples.
    • Sensitivity to investigate any biomolecular interaction using as little as 10µg of protein.
    • Samples presented in temperature controlled 96-well plate.
    • Fully automated system with walk-away operation for enhanced productivity.

    MicroCal PEAQ-ITC Analysis software offers experiment design simulation, batch evaluation of large data sets, automated assessment of data quality and a streamlined user interface that guides the user to final figures and presentation quality graphs quickly and easily.

    • Open multiple experiments in a single session.
    • Supports many automated fitting models.
      • Dissociation.
      • Enzyme Kinetics - Multiple Injections.
      • Enzyme Kinetics - Single Injection.
      • One Set of Sites.
      • Sequential Binding Sites.
      • One Set of Sites - SIM.
      • Two Sets of Sites.
      • Competitive.
    • Automated assessment of data quality.
      • Good quality data - Binding.
      • Good quality data - No binding.
      • Poor quality data - Check data.
    How it works

    Isothermal titration microcalorimeters measure the heat change that occurs when two molecules interact. Heat is released or absorbed as a result of the redistribution and formation of non-covalent bonds when the interacting molecules go from the free to the bound state. ITC monitors these heat changes by measuring the differential power, applied to the cell heaters, required to maintain zero temperature difference between the reference and sample cells as the binding partners are mixed. The reference cell usually contains water, while the sample cell contains one of the binding partners (the sample, often but not necessarily a macromolecule) and a stirring syringe which holds the other binding partner (the ligand). The ligand is injected into the sample cell, typically in 0.5 to 2 μL aliquots, until the ligand concentration is two- to three-fold greater than the sample. Each injection of ligand results in a heat pulse that is integrated with respect to time and normalized for concentration to generate a titration curve of kcal/mol vs molar ratio (ligand/sample). The resulting isotherm is fitted to a binding model to generate the affinity (KD), stoichiometry (n) and enthalpy of interaction (ΔH).

    MicroCal PEAQ ITC Microcalorimeters for microcalorimetry and label free analysis using isothermal titration calorimetry

    MicroCal PEAQ ITC Microcalorimeters for microcalorimetry and label free analysis using isothermal titration calorimetry

     
    Global network

    Our global sales and support network ensures that wherever you are, we’ve got you covered

     
    Free content

    Free access to exclusive content: webinars, videos, whitepapers, and much more

     
    Wide range of solutions

    Whatever your application or industry, we have the solutions, support, and expertise you need

     
    Quality you can trust

    Innovative, yet robust and reliable instruments you can trust for continuous, precise, and rapid analysis

    Specification
    Measurement type Affinity (KD)
    Measurement type Enthalpy ∆H
    Measurement type Entropy ∆S
    Measurement type Stoichiometry (n)
    Sample capacity 384 (four 96 well plates)
    Sample tray temperature range 4°C ± 2°C at ambient
    Sample volume 370 µL
    Cell volume 200 µL
    Injection syringe volume 40 µL
    Injection volume precision < 1% @ 2 µL
    Throughput Up to 42 per 24 h (SIM)
    Cell material Hastelloy
    Cell Coin-shaped
    Noise 0.15 ncal/s
    Temperature range 2°C to 80°C
    Temperature stability ±0.00012°C
    Response time 8 s*
    Multiple feedback modes Yes (passive, high gain, low gain)
    Notes *The MicroCal PEAQ-ITC Instrument Response Time is a true time constant.  It is the time interval between the first deviation away from the baseline, and the point on the peak that is 63% of the maximum peak height.
    Operating Environment
    Temperature (operating) 10°C to 28°C
    Humidity 0% to 70% RH, non condensing
    Electrical ratings
    Power Supply 100 - 240 V, 50/60 Hz, 400 W
    Weight 91 kg
    Dimensions (W, D, H) 63 x 58 x 77 cm
    Support

    Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

    When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

    bio-equip.cn
    We draw on the power of our analytical instruments and services to make the invisible visible and the impossible possible. Through the chemical, physical and structural analysis of materials, our high-precision analytical systems and top-notch services support our customers in creating a better world, helping them to improve everything from the energies that power us and the materials we build with, to the medicines that cure us and the foods we enjoy. We partner with many of the world’s biggest companies, universities and research organizations. They value us not only for the power of our solutions, but also for the depth of our expertise, collaboration and integrity. With over 2200 employees, we serve the world, and we are part of Spectris plc, the world-leading precision measurement group.
    Malvern Panalytical. We’re BIG on small?.
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.