Home >Products> Other Lab Equipments >Miscellaneous> MicroCal PEAQ-DSC
Other Lab Equipments:  Drug Tests / Pharmaceutics   Environmental Monitors   Food & Beverage   Radioactivity / Luminescence   Miscellaneous  
MicroCal PEAQ-DSC
MicroCal PEAQ-DSC
Place of Origin:
Netherlands
Brand:
Malvern Panalytical
Model:
Price:
Hits:
353 
Updated:
2/23/2022
  • Product Detail
  • Company Profile
    MicroCal PEAQ-DSC
    Gold standard protein stability analysis for research applications

    The MicroCal PEAQ-DSC system provides highly sensitive, easy-to-use microcalorimetry that helps reduce the time and cost associated with stability testing and comparability analysis.  The MicroCal PEAQ-DSC is a manual instrument with a cleaning device, which can be upgraded to an automated version upon request.

    Data generated by the MicroCal PEAQ-DSC provides critical guidance for biopharmaceutical development in protein engineering, (pre)formulation development, process development, manufacturing change control and biosimilarity and biocomparability studies. The integrated software streamlines workflows, facilitates non-subjective data analysis, performance qualification and compliance with 21 CFR Part 11 and Annex 11 regulations, all delivering high integrity data and driving productivity in biopharmaceutical research.

    Features and benefits
    Differential Scanning Calorimetry (DSC) is a powerful analytical tool for characterizing the thermal stability of proteins and other biomolecules. The technique measures the enthalpy (ΔH) and temperature (Tm) of thermally-induced structural transitions of molecules in solution. This information provides valuable insights into factors that stabilize or destabilize proteins, nucleic acids, micellar complexes and other macromolecular systems. The data are used to predict shelf-life of biomolecular products including biopharmaceuticals, to enable batch-to-batch and biosimilar versus innovator molecule comparisons, to develop purification strategies, to characterize and evaluate protein constructs, and to rank the affinities of ligands to their protein targets in small molecule drug discovery programs.
    The high-sensitivity MicroCal PEAQ-DSC system features automated data analysis to support the generation of high integrity thermal stability data and deliver compliance with regulatory requirements, whilst allowing easy integration into existing data handling and transfer systems. Unattended operation of the instrument after sample loading frees operator time.  This complete system requires no additional accessories, reagents or consumables.
    Key Features
    • Gold standard stability-indicating technique requiring minimal assay development
    • Direct and label-free measurement of biomolecular native-state stability in solution 
    • Measurement of very tight binding constants, up to 1020M-1
    • Manual system with pipette and cleaning device
    • Powerful MicroCal PEAQ-DSC software minimizes typical data analysis time and includes:
      • PEAQ-Compliance: The system is available with Malvern Access Controller (MAC) to limit access to user-defined SOPs and data analysis features. Data can be displayed using the Report Generator with user details and the ability to sign using electronic signatures to facilitate the integration of the workflow into your company’s quality system and aid compliance with 21 CFR Part 11 and Annex 11 regulations. This is provided as an optional accessory
      • PEAQ-Performance: Automatically detects and validates system readiness for optimal performance
      • PEAQ-Smart (including PEAQ-Finder): For SOP-based operation and data analysis.  Provides new algorithms to detect even subtle peaks and shoulders, facilitating the automatic, non-subjective identification of multiple transitions, such as those seen in multi-domain proteins
      • PEAQ-Compare: For the quantitative comparison of DSC traces for comparability studies, ideal for batch-to-batch and biosimilarity studies
      • Network-ready: email updates sent during the analysis to keep you informed of assay progress


    The MicroCal PEAQ-DSC Automated, with an autosampler, is also available.
    How it works
    Functional structures formed by proteins and other macromolecules often undergo temperature-induced conformational changes, such as unfolding. These changes result in the absorption of heat as a result of the redistribution of non-covalent bonds within the molecule. Differential Scanning Calorimeters measure this heat uptake very precisely.
    The thermal core of the MicroCal PEAQ-DSC system contains a sample cell (containing the sample of interest) and a reference cell (containing a matched buffer solution), both of which are housed within an insulating jacket. These two cells are always maintained at the same temperature, and during a measurement, they are heated at a constant scan rate. 
    As the molecule within the sample cell unfolds, heat is absorbed, creating a temperature difference (ΔT) between the sample cell and the reference cell. This results in a thermal gradient across the Peltier units, creating a proportional voltage, which is in turn converted to power to form a feedback loop to the Peltier units, in order to return ΔT to zero.
    Since protein unfolding is an endothermic event, it is observed as a positive displacement in the thermogram. The midpoint of this protein ‘melting’ transition is the Tm, and the area under the curve is the enthalpy (ΔH) of the unfolding process (please see figure below).
    MicroCal-PEAQ-DSC-Automated-How-It-Works

    Data analysis and measured/derived parameters are described in greater detail on the Differential Scanning Calorimetry technology page.
     
    Global networkOur global sales and support network ensures that wherever you are, we’ve got you covered
     
    Free contentFree access to exclusive content: webinars, videos, whitepapers, and much more
     
    Wide range of solutionsWhatever your application or industry, we have the solutions, support, and expertise you need
     
    Quality you can trustInnovative, yet robust and reliable instruments you can trust for continuous, precise, and rapid analysis
    Specification
    General
    Technology Differential Scanning Calorimetry
    Measurement type
    Temperature midpoint (TM)
    Enthalpy (ΔH)
    Heat capacity change (ΔCp)
    Cell
    Cell Capillary
    Cell material Tantalum
    Cell volume 130 μL
    Sample
    Sample volume 250 µL (manual filling)
    Typical sample concentration 0.01 mg/mL – 10 mg/mL 1
    Sample throughput ≤6 samples analyzed/8h
    System
    Noise 0.05 μCal/°C 2
    Baseline repeatability 1 μCal/°C 2
    Response time 5s 2
    Repeatability <0.2 µCal/°C 3
    Reproducibility <0.08°C St. Dev. TM and <2% RSD on ΔH 4
    System reproducibility <0.1°C St. Dev. TM and <5% RSD on ΔH 4
    Multiple feedback modes Yes (passive, high gain and low gain)
    Temperature range 2°C to 130°C 2,5
    Maximum scan rate 240°C/h
    Reverse scanning Yes
    Pressure perturbation calorimetry (PPC) N/A - manual cleaning device with guided workflows
    Cleaning solvents Water and detergent (Contrad 90) used as standard
    Software
    21 CFR part 11 Yes, with PEAQ-Compliance software option
    Network ready Yes, with email alert capability
    Operating environment
    Operating temperature (°C) +10°C to +28°C
    Storage temperature -20°C to +50°C
    Humidity 10% to 70%, non-condensing (10% to 90% for storage)
    Ingress Protection (IP) rating IP21
    Power 100-240 V A/C, 50/60 Hz, 70 W (cell), PC as supplied
    Certification CE (EN61010-1), EMC (EN61326-2-1, EN61326-1, FCC, ICES, VCCI), ISO9001:2008
    Weight and dimensions
    Dimensions (W, D, H) 20 cm × 44 cm × 19 cm
    Weight 8.2 kg
    Notes
      1 Sample dependent
    2 Typical results for ribonuclease (RNase) in 50 mM KAc buffer at pH 5.5, at 60°C/h with high feedback
    3 Rescans of a stable buffer
    4 Using ribonuclease (RNase)
    5 Range may be extended down to -10°C upon request

    Key applications
    MicroCal PEAQ-DSC instruments provide value to a wide range of applications, some of which are outlined below.
    Protein Characterization 
    MicroCal PEAQ-DSC is a fundamental tool for characterizing proteins. Key questions such as;
    • Is my protein folded?
    • In what conditions is my protein stable?
    • Is the protein multi domain?
    • Does my protein bind a ligand or cofactor?

    Webinar: The Power of Heat: Digging Deeper with Differential Scanning Calorimetry to Study Key Protein Characteristics 

    Webinar: Value of DSC in characterization and optimization of protein stability as compared to other thermal stability assays

    Liposomes

    Liposomes are used as model membrane systems and as potential drug delivery systems. ‘Structure Activity Relationships’ (SAR) of membrane components and drug uptake into a liposomes can be investigated monitoring shifts in the phase transition temperatures and enthalpies measured by DSC. Indeed, any material that forms micelles or other macromolecular structures can be studied using the technique.

    Webinar: Good practice for studying the stability of liposomes, their use as model systems and in drug delivery

    Application note: Using DSC to characterize thermotropic phase transitions in lipid bilayer membranes: The basics of liposome sample preparation and DSC studies 

    bio-equip.cn
    We draw on the power of our analytical instruments and services to make the invisible visible and the impossible possible. Through the chemical, physical and structural analysis of materials, our high-precision analytical systems and top-notch services support our customers in creating a better world, helping them to improve everything from the energies that power us and the materials we build with, to the medicines that cure us and the foods we enjoy. We partner with many of the world’s biggest companies, universities and research organizations. They value us not only for the power of our solutions, but also for the depth of our expertise, collaboration and integrity. With over 2200 employees, we serve the world, and we are part of Spectris plc, the world-leading precision measurement group.
    Malvern Panalytical. We’re BIG on small?.
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.