Low-temperature Thermostat Bath
DC series of low-temperature thermostat bath main performance Description:
1. All closed refrigeration compressor, refrigeration system is overheating, over-current protection device of multiple
2. Circulating pump can be constant temperature liquid tank outside the guidelines, a second constant temperature field.
3. Tank of cold liquid can be introduced outside, cooler outside the experimental container, but also in the slot directly to low-temperature, constant temperature experiment
4. Using XMT analog and digital PID control system, temperature digital display.
5. Liner, countertops are stainless steel, clean, beautiful and corrosion resistance.
Model
|
Temperature range (℃)
|
Temperature fluctuation (℃)
|
Work tank size (mm3)
|
Slot depth (mm)
|
Circulation pump flow (L/min)
|
Working slot opening (mm2)
|
DC-0506
|
-5~100
|
±0.05
|
250×200×150
|
150
|
4
|
180×140
|
DC-0510
|
-5~100
|
±0.05
|
250×200×200
|
200
|
4
|
180×140
|
DC-1015
|
-5~100
|
±0.05
|
280×250×220
|
220
|
4
|
235×160
|
DC-1020
|
-5~100
|
±0.05
|
280×250×280
|
280
|
4
|
235×160
|
DC-0530
|
-5~100
|
±0.05
|
400×325×230
|
230
|
13
|
310×280
|
DC-1006
|
-10~100
|
±0.05
|
250×200×150
|
150
|
4
|
180×140
|
DC-1010
|
-10~100
|
±0.05
|
250×200×200
|
200
|
4
|
180×140
|
DC-1030
|
-10~100
|
±0.05
|
400×325×230
|
230
|
13
|
310×280
|
DC-2006
|
-20~100
|
±0.05
|
250×200×150
|
150
|
4
|
180×140
|
DC-2010
|
-20~100
|
±0.05
|
250×200×200
|
200
|
4
|
180×140
|
DC-2015
|
-20~100
|
±0.05
|
300×250×200
|
200
|
4
|
235×160
|
DC-2020
|
-20~100
|
±0.05
|
280×250×280
|
280
|
4
|
235×160
|
DC-2030
|
-20~100
|
±0.05
|
400×325×230
|
230
|
13
|
310×280
|
DC-3005A
|
-30~100
|
±0.1
|
250×200×120
|
120
|
4
|
180×140
|
DC-3006
|
-30~100
|
±0.1
|
250×200×150
|
150
|
4
|
180×140
|
DC-3010
|
-30~100
|
±0.1
|
250×200×200
|
200
|
4
|
180×140
|
DC-3015
|
-30~100
|
±0.1
|
300×250×200
|
200
|
4
|
235×160
|
DC-3020
|
-30~100
|
±0.1
|
280×250×280
|
280
|
4
|
235×160
|
DC-3030
|
-30~100
|
±0.1
|
400×325×230
|
230
|
13
|
310×280
|
DC-4006
|
-40~100
|
±0.1
|
250×200×130
|
130
|
4
|
180×140
|
DC-4010A
|
-40~100
|
±0.1
|
310×210×150
|
150
|
4
|
185×180
|
DC-4010B
|
-40~100
|
±0.1
|
250×200×200
|
200
|
4
|
180×140
|
DC-4015
|
-40~100
|
±0.1
|
300×250×200
|
200
|
4
|
235×160
|
DCW-0506
|
-6~100
|
±0.05
|
250×200×150
|
150
|
6
|
180×140
|
DCW-1015
|
-10~100
|
±0.05
|
280×250×220
|
220
|
4
|
235×160
|
DCW-2008
|
-20~100
|
±0.05
|
280×250×140
|
140
|
4
|
235×160
|
DCW-3506
|
-35~100
|
±0.1
|
250×200×150
|
150
|
4
|
180×140
|
DCW-3510
|
-35~100
|
±0.1
|
250×200×200
|
200
|
4
|
180×140
|
DCW-4006
|
-40~100
|
±0.1
|
250×200×130
|
130
|
6
|
180×140
|
bio-equip.cn