    INTENDED USE

    The  Chagas Ab Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgG anti-Trypanosoma cruzi (T. cruzi) in human serum, plasma or whole blood. It is intended to be used as a screening test and as an aid in the diagnosis of infection with T. cruzi.  Any reactive specimen with the  Chagas Ab Combo Rapid Test must be confirmed with alternative testing method(s) and clinical findings.

    TEST PRINCIPLE

    The  Chagas Ab Combo Rapid Test is a lateral flow chromatographic immunoassay based on the principle of indirect immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing Protein A conjugated with colloid gold (Protein A conjugates), 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre-coated with recombinant T. cruzi antigens, and the C band is pre-coated with anti-Protein A antibodies.

     

     1.jpg 

     

    When an adequate volume of test specimen is dispensed into the sample well of the test cassette, the specimen migrates by capillary action across the cassette.  The IgG antibodies to T. cruzi if present in the specimen will bind to the Protein A conjugates. The immunocomplex is then captured on the membrane by the pre-coated T. cruzi antigens, forming a burgundy colored T band, indicating a Chagas Ab positive test result. 

    Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of anti-protein A antibody-Protein A gold conjugates regardless of color development on the T band. Otherwise, the test result is invalid and the specimen must be retested with another device.

    REAGENTS AND MATERIALS PROVIDED

    1.Each kit contains 30 test devices, each sealed in a foil pouch with three items inside:

    a. One cassette device.      

    b. One plastic dropper.

    c. One desiccant.

    2.Sample diluent (1 bottle, 5 mL)

    3.One package insert (instruction for use).

    MATERIALS REQUIRED BUT NOT PROVIDED

    1.Clock or Timer

    2.Lancing device for whole blood test

    3.Pipette and tips capable of delivering 20 µL volumes with a precision better than 1.5%. 

    WARNINGS AND PRECAUTIONS

    For in Vitro Diagnostic Use

    1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results.
    2. Do not open the sealed pouch, unless ready to conduct the assay.
    3. Do not use expired devices.
    4. Bring all reagents to room temperature (15°C -30°C) before use.
    5. Do not use the components in any other type of test kit as a substitute for the components in this kit.
    6. Do not use hemolized blood specimen for testing.
    7. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test.
    8. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens.
    9. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 
    10. Dispose of all specimens and materials used to perform the test as biohazardous waste.
    11. Handle the Negative and Positive Control in the same manner as patient specimens. 

    The testing results should be read within 15 minutes after a specimen is applied to 

    1.the sample well or sample pad of the device. Reading result after 15 minutes may give erroneous results. 

    2.Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning.

    REAGENT PREPARATION AND STORAGE INSTRUCTIONS

    All reagents are ready to use as supplied. Store unused test devices unopened at 2°C-30°C.  The positive and negative controls should be kept at 2°C-8°CIf stored at 2°C-8°C, ensure that the test device is brought to room temperature before opening. The test device is stable through the expiration date printed on the sealed pouch. Do not freeze the kit or expose the kit over 30° 

    ASSAY PROCEDURE

     Step 1: Bring the specimen and test components to room temperature if refrigerated or frozen. Mix the specimen well prior to assay once thawed.

     Step 2: When ready to test, open the pouch at the notch and remove device. Place the test device on a clean, flat surface.

     Step 3: Be sure to label the device with specimen’s ID number.

     Step 4:      For serum or plasma test

                    - Dispense5 µL of the specimen into the sample well

                    - Then add 2 drops (about 70-100 µL) of Sample Diluent immediately

        2.jpg    

    Step 5: Set up timer. 

    Step 6: Results can be read in 15 minutes. Positive results can be visible in as short as 1 minute.

     Don’t read result after 15 minutes.  To avoid confusion, discard the test device after interpreting the result. 

    QUALITY CONTROL

     Using individual  Chagas Ab Combo Rapid Test cassettes as described in the Assay Procedure above, run 1 Positive Control and 1 Negative Control (provided upon request) under the following circumstances to monitor test performance:

     1.A new operator uses the kit, prior to performing testing of specimens.

     2.A new test kit is used.

    3.A new shipment of kits is used.

    4.The temperature used during storage of the kit falls outside of 2°C-30°C.

    5.The temperature of the test area falls outside of 15°C-30°C.

    6.Expected results are as follows:

    Negative Control

    Only the C band shows color development. The T band shows no color development.

     A.jpg 

        Positive Control

       Both C and T bands show color development.

     

       B.jpg          

         The appearance of any burgundy color in the T band, regardless of the intensity, must be    considered as presence of the band.

    INTERPRETATION OF ASSAY RESULT

    1.NEGATIVE RESULT: If only the C band is developed, the test indicates that no detectable anti -T. cruzi antibody present in the specimen. The result is negative.

    C.jpg 

     2.POSITIVE RESULT: If both C and T bands are developed, the test indicates for the presence of anti -T. cruzi antibody in the specimen. The result is positive.

    B.jpgD.jpg 

      Samples with positive results should be confirmed with alternative testing method(s) and clinical findings before a positive determination is made. 

    3.INVALID: If no C band is developed, the assay is invalid regardless of color development on the T band as indicated below. Repeat the assay with a new device.  

    E.jpgF.jpg 

     PERFORMANCE CHARACTERISTICS

     Clinical Performance

     A total of 214 samples from susceptible subjects were tested by the  Chagas Ab Combo Rapid Test and by a commercial IgG EIA test. Comparison for all subjects is showed in the following table: 

     

     Chagas Ab Combo Rapid Test 

     

    IgG EIA

    Positive

    Negative

    Total

    Positive

    13

    1

    14

    Negative

    0

    200

    200

    Total

    13

    201

    214

    Relative Sensitivity:  92.9% , Relative Specificity:  100%, Overall Agreement:   99.5%

    bio-equip.cn
    Zhuhai Encode Medical Engineering Co.,Ltd (herinafter referred to as Encode) was established in 1994, as one of the earliest
    and largest manufacturers of in-vitro diagnostic field in China. Encode specializes in R&D, production and distribution of in-vitro diagnostic products. As a hi-tech and innovative enterprise, we have researched and developed series of microbiological diagnostic productds and immunology diagnostic rapid tests, which are used for diagnosis of infection disease, cardiac markers, tumor markers, fertility test, durgs of abuse and sexual transmitted disease.

    Encode occupies a land of 15,000 m2 in Zhuhai. There are 2,000 GMP standard clean workshops of microbiology diagnostic products, colloidal gold diagnostic products and molecular with automatic manufacturing lines and passed the quality management system evaluation by SFDA and GDFDA.

    Encode has established extensive cooperation with research centers in universtities, such as Lanzhou University, South China University of Technology, Jinan University and Shanghai Plumonary Hospital, etc. Whith strong R&D and technological innovation capability. Encode ranks leading level in terms of IVD industries field in China. We have also obtained ISO 13485:2003, ISO 9001:2001, CE and have been granted the title of national hi-tech enterprise.

    Today, we provide medical products and health care solution to clients not only in China, but also worldwide, such as Europe, Africa, Middle East, South East, Asia etc.

    With the experience and dedication of the scientific staffs, Zhuhai Encode Medical Engineering Co.,Ltd will continue our endeavor to provide professional in-vitro diagnostic products and health care solutions to the worldwide and make our contributions to the career of human health.
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.