TOPSCIEN Variable Volume Micropipettes are product of intensive ergonomic and operational studies and the application of modern innovative materials . They are the perfect manual pipettes for demanding laboratory applications for scientists who prefer central pipetting buttons .
The Micropipettes provide all of the features required by users working in the Iife sciences field.
Robust , One-handed operation , Easy calibration institutions , completely auto clavable , high precision and Easy Calibration technique for lasting reliability .
Features :
Large central pipetting button and separate ejection function
True one-handed operation for both right-and left-handers
Completely autoclavable at 121℃ ( 20 min ) volume-change protection
4-Position volume display , always clearly visible Easy Calibration technique- readjustment without Special tools
Changes from factory settings are clearly visible extemally .
Short stroke of only 12.5 mm to reduce the risk of RSI ( Repetitive Strain Injury )
Corrosion-resistant piston and ejector
Color-coded for easy selection of the right tip CE-compliant
P Series Variable Volume Single Channel Micropipette (121℃ autoclavable)
Cat.No.
|
Code.No.
|
Volume
μl
|
Increment
μl
|
A*≤±%
|
CV*≤%
|
8011179
|
TP1H
|
0.1-1μl
|
(0.001ul)
|
2
|
1.2
|
8011180
|
TP10H
|
0.5-10μl
|
(0.01ul)
|
1
|
0.5
|
8011181
|
TP20H
|
2-20μl
|
(0.02ul)
|
0.8
|
0.4
|
8011182
|
TP100H
|
10-100μl
|
(0.1ul)
|
0.6
|
0.2
|
8011183
|
TP200H
|
20-200μl
|
(0.2ul)
|
0.6
|
0.2
|
8011184
|
TP1000H
|
100-1000μl
|
(1ul)
|
0.6
|
0.2
|
8011185
|
TP5000H
|
500-5000μl
|
(5ul)
|
0.6
|
0.2
|
8011186
|
TP10000H
|
1000-10000μl
|
(10ul)
|
0.6
|
0.2
|
P Series Variable Volume Single Channel Micropipette ( Ejector 121℃ autoclavable)
Cat.No.
|
Code.No.
|
Volume
μl
|
Increment
μl
|
A*≤±%
|
CV*≤% |
8011189
|
TP1
|
0.1-1μl
|
(0.001ul)
|
2
|
1.2
|
8011190
|
TP10
|
0.5-10μl
|
(0.01ul)
|
1
|
0.5
|
8011191
|
TP20
|
2-20μl
|
(0.02ul)
|
0.8
|
0.4
|
8011192
|
TP100
|
10-100μl
|
(0.1ul)
|
0.6
|
0.2
|
8011193
|
TP200
|
20-200μl
|
(0.2ul)
|
0.6
|
0.2
|
8011194
|
TP1000
|
100-1000μl
|
(1ul)
|
0.6
|
0.2
|
8011195
|
TP5000
|
500-5000μl
|
(5ul)
|
0.6
|
0.2
|
8011196
|
TP10000
|
1000-10000μl
|
(10ul)
|
0.6
|
0.2
|
Calibrated to deliver (TD. Ex) Error limits according to the nominal capacity (=maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20℃,and with smooth, steady operation The error limits are within the limits of DIN EN IS0 8655-2. Conformity certified to DIN 12
600.A=Accuracy, CV =Coefficient of variation
bio-equip.cn