Easy Handling
A particular advantage of the new multichannel pipette is the easy operation , e.g., when performing serial pipetting of immunological assays , while making serial dilutions or when filling 96-well plates for cell cultures . Use the Innovative material will be more lighter . Pipetting easy and convenient
Reduce the risk for hands injury when repetitive pipetting .
It can be operated comfortably whether large hands or small hands ,
The ergonomiCelly finger rest takes the load off the hand , not need to grip the pipette tightly , so the pipetting operations can be completed with the fatigue . True one-hand operated
The one hand can be change the volume and fix the volume easyly and conveniently .
The large pipetting button will be saved pipetting strength .
Pisto n corrosion proof
Lightweight-Accurate-low force
The piston-operated Micropipettes provides maximum versatility and optimum quality over the entire volume range.
There are 5 different volume 8 and 12chennels micropipette which the volume cover 0.5-300ul
Features :
The TOPSCIEN multichannel Micropipette have the Iight weigh,operated with light pipetting strength and easily and conveniently .
High chemical and UV resistance
Fully autoclavable
Rotating dispensing head for optimal pipetting Convenience .
Due to the optimized standard design for the tip cone which it can be compatible with a wide range band of tips
A central pipetting button, the one-handed operation, precise 4-position volume settings and a volume display that can be easily read by both right- and left-handed operators are only a few examples of the attention to detail in the design of the TOPSCIEN Variable Volume Micropipette
P Series Variable Volume 8 Channel Micropipette (121℃ autoclavable )
Cat.No
|
Code. No.
|
Volume
|
Volume range
μl
|
Volume step
μl
|
A*≤±%
|
CV*≤%
|
Increment
μl
|
Type of tips
μl
|
8011260
|
TP8D10H
|
0.5-10
|
10/5/1
|
1.6/2/8
|
1.0/2/6
|
0.01
|
20
|
8011261
|
TP8D50H
|
5-50
|
50/25/5
|
0.8/1.4/6
|
0.4/0.8/3
|
0.05
|
200
|
8011262
|
TP8D100H
|
10-100
|
100/50/10
|
0.8/1.4/4
|
0.3/0.6/2
|
0.1
|
200/300
|
8011263
|
TP8D200H
|
20-200
|
200/100 /20
|
0.8/1.4/4
|
0.3/0.6/1.5
|
0.2
|
200/300
|
8011264
|
TP8D300H
|
30-300
|
300/150/30
|
0.6/1.2/3
|
0.3/0.6/1.5
|
0.3
|
300
|
P Series Variable Volume 8 Channel Micropipette( Ejector 121℃ autoclavable)
Cat.No
|
Code. No.
|
Volume
|
Volume range
μl
|
Volume step
μl
|
A*≤±%
|
CV*≤%
|
Increment
μl
|
Type of tips
μl
|
8011270
|
TP8D10
|
0.5-10
|
10/5/1
|
1.6/2/8
|
1.0/2/6
|
0.01
|
20
|
8011271
|
TP8D50
|
5-50
|
50/25/5
|
0.8/1.4/6
|
0.4/0.8/3
|
0.05
|
200
|
8011272
|
TP8D100
|
10-100
|
100/50/10
|
0.8/1.4/4
|
0.3/0.6/2
|
0.1
|
200/300
|
8011273
|
TP8D200
|
20-200
|
200/100 /20
|
0.8/1.4/4
|
0.3/0.6/1.5
|
0.2
|
200/300
|
8011274
|
TP8D300
|
30-300
|
300/150/30
|
0.6/1.2/3
|
0.3/0.6/1.5
|
0.3
|
300
|
P Series Variable Volume 12 Channel Micropipette (121℃ autoclavable )
Cat.No
|
Code. No.
|
Volume
|
Volume range
μl
|
Volume step
μl
|
A*≤±%
|
CV*≤%
|
Increment
μl
|
Type of tips
μl
|
8011280
|
TP12D10H
|
0.5-10
|
10/5/1
|
1.6/2/8
|
1.0/2/6
|
0.01
|
20
|
8011281
|
TP12D50H
|
5-50
|
50/25/5
|
0.8/1.4/6
|
0.4/0.8/3
|
0.05
|
200
|
8011282
|
TP12D100H
|
10-100
|
100/50/10
|
0.8/1.4/4
|
0.3/0.6/2
|
0.1
|
200/300
|
8011283
|
TP12D200H
|
20-200
|
200/100 /20
|
0.8/1.4/4
|
0.3/0.6/1.5
|
0.2
|
200/300
|
8011284
|
TP12D300H
|
30-300
|
300/150/30
|
0.6/1.2/3
|
0.3/0.6/1.5
|
0.3
|
300
|
P Series Variable Volume 12 Channel Micropipette( Ejector 121℃ autoclavable)
Cat.No
|
Code. No.
|
Volume
|
Volume range
μl
|
Volume step
μl
|
A*≤±%
|
CV*≤%
|
Increment
μl
|
Type of tips
μl
|
8011290
|
TP12D10
|
0.5-10
|
10/5/1
|
1.6/2/8
|
1.0/2/6
|
0.01
|
20
|
8011291
|
TP12D50
|
5-50
|
50/25/5
|
0.8/1.4/6
|
0.4/0.8/3
|
0.05
|
200
|
8011292
|
TP12D100
|
10-100
|
100/50/10
|
0.8/1.4/4
|
0.3/0.6/2
|
0.1
|
200/300
|
8011293
|
TP12D200
|
20-200
|
200/100 /20
|
0.8/1.4/4
|
0.3/0.6/1.5
|
0.2
|
200/300
|
8011294
|
TP12D300
|
30-300
|
300/150/30
|
0.6/1.2/3
|
0.3/0.6/1.5
|
0.3
|
300
|
Calibrated to deliver (TD. Ex) Error limits according to the nominal capacity (=maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20℃,and with smooth, steady operation The error limits are within the limits of DIN EN IS0 8655-2. Conformity certified to DIN 12
600.A=Accuracy, CV =Coefficient of variation
bio-equip.cn