Features
* Two measuring methods: magnetic induction (F) and eddy current (N)
* Two measurement mode: Single and Continuous(Notice:Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Automatic memory of calibration value,and automatic recognize the substrate.
* Operation process have buzzing reminder,while no buzzing in continuous mode.
* Use USB/RS-232 data output to connect with PC.
* Provide Bluetooth data output choice.
* Separate Type can provide several type probe, measure can be more flexibility.
Principles |
Applications |
Examples |
F Type
Magnetic Induction
(Iron Base) |
Measure the thickness of non-magnetic materials on magnetic materials |
Galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper etc |
NF Type
Eddy Current
(Aluminium Base) |
Measure the thickness of non-conductive coatings on non-magnetic metals |
Anodizing, varnish, paint, enamel, plastic coatings, powder, etc. Applied to aluminum, brass, non-magnetic stainless steel, etc |
Principle
|
NF Type Eddy Current / F Magnetic Induction
|
Range
|
0~1250µm/0~50mil
|
Resolution
|
0.1µm/1µm
|
Accuracy
|
±1~3%n or ±2.5µm
|
Min.Radius Workpiece
|
F Type:convex 1.5mm/concave 25mm
|
NF Type:convex 3mm/concave 50mm
|
Min.Measuring Area
|
6mm
|
Min.Sample Thickness
|
0.3mm
|
Metric/Imperial
|
Convertible
|
Battery Indicator
|
Low Battery Indicator
|
Automatic Power Off
|
√
|
Operating Conditions
|
Temperature:0~50ºC
|
Humidity:<80%RH
|
Power Supply
|
4x1.5V AAA (UM-4)Battery
|
Dimensions
|
126x65x27mm
|
Weight
|
81g(Not Including Batteries)
|