The GP1 Data Logger is a complete logging solution housed in a waterproof IP67 enclosure with battery power. The internal memory can hold >600,000 readings – more than enough for one year’s operation (typical).

ut connections |
2 voltage channels |
2 temperatures or 2 additional SM150T Sensors [3] |
2 counters (33 kHz & 50 Hz) |
1 WET Sensor |
Control outputs |
1 relay (1 A) |
Readings stored |
600,000 |
Recording rate |
1 second to 24 hours |
Configuration |
DeltaLINK |
Communication options |
RS232 USB [1] or modem |
Sensor excitation |
1 switched logger power
15 V precision reference |
Power |
9 V 6LR61 (PP3) alkaline or external power 11-24 V |
Battery life (dependent on usage) |
>76k readings
lasting >130 days |
Enclosure rating |
IP67 |
Temperature range |
-20 to +60°C |
Display |
– |
Size |
140 x 105 x 45 mm |
Typical applications |
Monitoring soil moisture |
General data logging |
Controlling irrigation |
Sensor compatibility (maximum number of sensors that could be connected [2] |
ML3 |
✓ (2) with temp ✓ (4) excl. temp [3] |
SM150T |
✓ (2) with temp ✓ (4) excl. temp [3] |
PR2 |
– |
PR2 SDI-12 |
– |
WET Sensor |
✓(1) |
EQ3 |
✓(2 as mV only) |
Temperature |
✓(2) |
Tensiometers (bridge sensors) |
✓(2) each requires GP-PBA-X50 |
Counters or Events |
✓(2) 1 fast 1 slow |
Relay Output |
✓(1) |
[1] With USB to RS232 Adapter Cable type USB-RS232
[2] With appropriate expansion cards and power supply arrangements
[3] Temperature channels provide only single-ended inputs so should not be used with long cables or in noisy environments when used with soil moisture sensors. The accuracy figures quoted for GP1 soil moisture readings do not apply to these resistance channels when configured as soil moisture inputs.
For full GP1 specification please see the GP1 data sheet or Quick Start Guide