Probes
|
PICO32
|
PICO64
|
Power
|
7~24V DC
|
7~24V DC
|
Power consumption
|
100mA@12V/DC for 2~3s
|
100mA@12V/DC for 2~3s
|
Measurement range
|
0~100%
|
0~100%
|
Accuracy (0~6dS/m)
|
±1%(0~40%);±2%(40~70%)
|
±1%(0~40%);±2%(40~70%)
|
Accuracy (6~12dS/m)
|
±2%(0~40%);±3%(40~70%)
|
±2%(0~40%);±3%(40~70%)
|
Accuracy (12~50dS/m)
|
————
|
————
|
Repeatability accuracy (0~6dS/m)
|
±0.2%
|
±0.2%
|
Repeatability accuracy (6~12dS/m)
|
±0.3%
|
±0.3%
|
Repeatability accuracy (12~50dS/m)
|
————
|
————
|
Temperature drift
|
0.3% of measurement range
|
0.3% of measurement range
|
Temperature measurement range
|
-15℃~50℃
|
-15℃~50℃
|
Temperature accuracy
|
±0.2℃
|
±0.2℃
|
Volume
|
0.25 L(110 mm×Ф50 mm)
|
1.25L(160 mm×Ф100 mm)
|
Operating temperature
|
-15℃~+50℃(Other temperature range can be customized)
|
-15℃~+50℃(Other temperature range can be customized)
|
Material
|
Waterproof PVC (IP68)
|
Waterproof PVC (IP68)
|
Size
|
155 x Ø32 mm
|
155 x Ø63 mm
|
Probe length
|
110mm
|
160mm
|
Probe diameter
|
3.5mm
|
6mm
|
Output
|
IMP-BUS,RS485, Analog output (0~1V or 4~20 mA)
|
IMP-BUS,RS485, Analog output (0~1V or 4~20 mA)
|
Cable length
|
5m
|
5m
|
Calibration
|
Standard calibration can apply to most standard soil types, store up to 15 user-defined calibration curves
|
Standard calibration can apply to most standard soil types, store up to 15 user-defined calibration curves
|