Login    Join free Add to favorites    中文
Home >Products> Other Lab Equipments >Drug Tests / Pharmaceutics> Winner2005 Automatic High Accuracy Laser Particle Size Analyzer For Metal Industry
Winner2005 Automatic High Accuracy Laser Particle Size Analyzer For Metal Industry
Winner2005 Automatic High Accuracy Laser Particle Size Analyzer For Metal Industry
Origin of place China
Model winner2005
Supplier Jinan Winner Particle Instrument Stock Co., Ltd.
Price please email or call us
Hits 980
Updated 12/29/2016
  • Product Detail
  • Company Profile

Winner2005A is intelligent full automatic laser diffraction particle size analyzer 

with principle of Mie Scattering to precisely determine the particle size distribution from 0.01 to 780 micrometer. It enables you understand materials well, such as

abrasives, adhesives, agrochemical,barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble,Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics, Diamond Powder, Dolomite, Diatomite,Emulsion, Environmental, Explosives, Ferrite, Flour, Fluorescent, Fluorite, Food & Beverage, Food Additive,Graphite, Grinding, Inks, Kaolin, Medicine, Metal Powder, Mica, Milling, Minerals,Oxides,Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers,Quartz,Refractory, Resins, Silica, slurry, Soil Sediments, Starch, Sulfur, Synthetics, Talc, Toners, Tourmaline,Wollastonite, Zeolite, Zirconium Silicate etc etc. Industry.

 

 

Main Specifications:

 

Model Name

Winner2005A

Standard

ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013

Principle

MIE scattering principle

Size range

0.01-780μm

Detector Channels

77 pcs

Accuracy

<1%   (Deviation of  D50 on national standard sample)

Repeatability

<1%   (Deviation of  D50 on national standard sample)

Laser

He-Ne Laser  λ= 632.8nm,  p>2mW

Auxiliary Laser: semiconductor λ= 650nm,p>2mW

service time>25000 hour

Wet dispersion

Ultrasonic

Frequency:40KHz   Power:35W,   Time: ≥1S

Agitator

Revolutions Speed: 0-300RPM (Adjustable)

Circulation

Rated Flow:8L/min    Rated Power:10W

Sample pool

Volume: 350mL

Operation mode

Manual and Full automatic, 2 mode, freely choose

Optical alignment system

Full automatic optical path alignment system

Software function

Analysis mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.

Statistic Method

Volume Distribution, Quantity Distribution

 

Statistic Comparison

Several Testing Results of samples

Different batches of samples testing result,

Samples before and after processing,

Test result of samples in different time.

 

User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries

Test Report

Word, Excel,Photo( Bmp), Text etc

Multiple-language Support

Multiple language Support

Intelligent operation

 Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor

Testing speed

<2min/time

Outer dimension

L85cm*W39cm*H45cm

Net weight

40Kg

 

Main Features:

 

1) Optical light system: Adopt orthogonal double laser beam patented technology, measure range expanded from 0.01-780μm.      

 

2)Intelligent operation mode realize one key test, automatically supply-water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.

 

3) Automatic optical light Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.

 

4)Wet sample dispersion system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment.

 

5)Software support: Original patent unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.

 

6) Output parameters:(D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98,set any value, S/V, D[3,2],D[4,3] )

 

Adopt Patents Technology:

 

  • Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
  • Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
  • MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
  • Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
  • Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号