1,Specifications
Type
|
Blood Bank Refrigerator
|
Cabinet Type
|
Upright
|
Climate Class
|
ST
|
Cooling Type
|
Forced air cooling
|
Defrost Mode
|
Auto
|
Refrigerant
|
CFC-Free
|
Noise Lever (dB)
|
42
|
Temperature Range(℃)
|
4±1
|
Controller
|
Microprocessor
|
Display
|
LED
|
Power Supply(V/Hz)
|
220-240/50
|
Power(W)
|
350
|
Electrical Current(A)
|
2.6
|
Capacity(L/Cu.Ft)
|
158/5.6
|
Blood Storage Capacity(450ml blood bags)
|
84
|
Net/Gross Weight(approx)
|
107/120(kg)
235.9/264.6(lbs)
|
Interior Dimensions(W*D*H)
|
455*370*1070(mm)
17.9*14.6*42.1(in)
|
Exterior Dimensions(W*D*H)
|
560*630*1530(mm)
22.0*24.8*60.2(in)
|
Packing Dimensions(W*D*H)
|
637*667*1647(mm)
25.1*26.3*64.8(in)
|
Container load (20'/40'/40'H)
|
27/54/54
|
High/Low Temperature
|
Y
|
Remote Alarm
|
Y
|
Power Failure
|
Y
|
Sensor Error
|
Y
|
Low Battery
|
Y
|
Door Ajar
|
Y
|
Caster
|
Y
|
Foot
|
Y
|
Test Hole
|
Y
|
Drawers
|
4
|
Temperature Recorder
|
Y
|
USB Interface
|
N/A
|
Certificate
|
CE
|
Standard
|
AABB DIN58371 BS4376-1:1991
|
2, Features
1> Adjustable Shelves
The shelves are adjustable to any height and satisfy different requirements
2> Three Alarm Functions
Audible buzzer, Visible flshing light,Remote alarm
3> Five Alarms Function
High/low temperature , Power failure, Door ajar, Senor error, Low battery
4> Condensation Free Design
Door without condensation under ambinet temp. 32℃ and 80% humidity: Electrical heating glass door, condensation free under humidity 80%
5> Intelligent Alarm
Human Technology, High Safety
6> Intelligent Alarm
Three alarm types keep storage safe
7> Famous Compressor
Energy Saving, More Reliable: International well-known brand compressor, and past the long-term verification, ensure the high reliability
8> Stainless Steel Drawer
Suitable for storing large volume materials at a time: Single drawer storage capacity equivalent to that of four blood storage boxes , which improves the efficiency
3, Other Features
1> Reliability
1) Field proven refrigeration system design and control system design
2) Consistent temperature performance
2> Key Features
1) Microprocessor controlled forced-air cooling with electrical heat compensation system
2) Consistent cabinet temperature 4±1℃ and 4±1.5℃ for HXC-1308/1308B
3) Digital temperature display for upper and lower sections in chamber with 0.1℃ resolution
4) Digital display of average temperature of the cabinet with 0.1℃ resolution
5) High-tech integrated sensors to display and control temperature
6) Standard temperature recorder (Optional for HXC-158)
7) Auto-defrost to remove moisture on cooling surface
8) Large digital display for ease of observation
9) Wide voltage range designed to operate in 187-242 V/AC
3> Safety
1) Dual displays of operational parameter(digital and temperature recorder display)
2)Built-in backup battery to display temperature and to operate audible and visual alarm systems for up to 48 hours without ac power
3) Three types of alarm alerts: buzzer, flashing light, and remote alarm
4) Five alarm conditions: high/low temperature, power failure, sensor error, door ajar, low voltage in backup battery
5) Automatic default operations
4> Ergonomic Design
1) Safety lock to prevent unauthorized access
2) Safety lock to prevent unauthorized access
3) Caster design and interior light
4) Optional baskets or stainless steel drawers
bio-equip.cn