BK-UV1000/BK-V1000/BK-UV1200/BK-V1200 UV/VIS SPECTROPHOTOMETER
Features:
●Large LCD screen (128*64 Dots)
●Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
● High-class grating , wholly hermetic light path design, ensures the super low stray light
●Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
●Pre-aligned design ensures the user can change lamps conveniently
●Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
●With Si02 coating optical mirror, reducing the pollution from outside fully
●Optional PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics
●Widely used for Organic chemistry, Inorganic chemistry, Life sciences, food, Medicine and health, Agriculture, Geology, Metallurgy and Environment etc. fields
Model
|
BK-UV1000
|
BK-V1000
|
BK-UV1200
|
BK-V1200
|
Optical System
|
Single Beam, Grating1200 lines/mm
|
Wavelength Range
|
200-1020nm
|
325-1000nm
|
200-1020nm
|
320-1020nm
|
Spectral Bandwidth
|
4nm
|
Wavelength Accuracy
|
±1.8nm
|
±1.5nm
|
Wavelength Repeatability
|
≤0.5nm
|
Photometric Accuracy
|
± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T)
|
Photometric Repeatability
|
0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)
|
Stray Light
|
≤0.1 % T @ 360nm; 220nm
|
≤0.2% T @ 360nm
|
Stability
|
± 0.001A / h @ 500nm
|
Noise
|
± 0.001A
|
Display
|
128*64 Dots LCD
|
Photometric Mode
|
T, A, C, E
|
Photometric Range
|
0-200%T,-0.301~3.0A
|
Detector
|
Silicon Photodiode
|
Light Source
|
Deuterium Lamp, Tungsten Lamp
|
Input
|
Membrane Keypad
|
Standard Accesseries
|
10mm glass cuvette *4 units 10mm quartz cuvette *2 units
|
10mm glass uvette *4 units
|
10mm glass cuvette *4 units 10mm quartz cuvette *2 units
|
10mm glass uvette *4 units
|
Power Supply
|
110V/220±10% ,60/50Hz
|
Packing Size(mm)
|
560*430*320
|
560*430*320
|
560*430*320
|
560*430*320
|
Gross Weight(kg)
|
12
|
11.5
|
12
|
11.5
|
BK-UV1800/UV1600/V1800/V1600 UV/VIS Spectrophotometer
Features:
⊙Large LCD screen(480*272 Dots) with 65 thousand true color and support U disk data saving
⊙Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
⊙ Data output: Data can be exported to U disk (USB Output)
⊙ Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
⊙ Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light
⊙Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
⊙Pre-aligned design ensures the user can change lamps conveniently
⊙With GLP self-check function, check the wavelength accuracy and Photometry accuracy, can provide test report and power-off protection
⊙Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
⊙With Si02 coating optical mirror, reducing the pollution from outside fully
⊙Optional PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics, Spectrum Scanning, DNA/Protein test
Model
|
BK-UV1800
BK-UV1800PC
|
BK-UV1600
BK-UV1600PC
|
BK-V1800
BK-V1800PC
|
BK-V1600
BK-V1600PC
|
Optical System
|
Single Beam, Grating1200 lines/mm
|
Wavelength Range
|
190-1100nm
|
320-1100nm
|
Spectral Bandwidth
|
2nm
|
4nm
|
2nm
|
4nm
|
Wavelength Accuracy
|
± 0.5nm
|
Wavelength Repeatability
|
≤0.2nm
|
Photometric Accuracy
|
± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T)
|
Photometric Repeatability
|
0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)
|
Stray Light
|
≤0.04% T @ 360nm; 220nm
|
≤0.04% T @ 360nm
|
Stability
|
± 0.001A / h @ 500nm
|
Baseline Flatness
|
± 0.002A
|
Noise
|
± 0.0005A
|
Display
|
480 * 272 65 thousand true color TFT LCD
|
Photometric Mode
|
T, A, C, E
|
Photometric Range
|
0-200% T,-0.301~3.0A
|
Detector
|
Silicon Photodiode
|
Light Source
|
Deuterium Lamp, Tungsten Lamp
|
Input
|
Membrane Keypad
|
Output
|
USB Print and data output, Connect PC
|
Standard Accesseries
|
10mm glass cuvette *4 units 10mm quartz cuvette *2 units
|
10mm glass uvette *4 units
|
Power Supply
|
110V/220±10% ,60/50Hz
|
Packing Size(mm)
|
620*500*370
|
620*500*370
|
620*500*370
|
620*500*370
|
Gross Weight(kg)
|
18
|
18
|
16.5
|
16.5
|
BK-UV1900/BK-V1900 SCANNING UV/VIS SPECTROPHOTOMETER
Model
|
BK-UV1900
BK-UV1900PC
|
BK-V1900
BK-V1900PC
|
Optical System
|
Single Beam, Grating1200 lines/mm
|
Wavelength Range
|
190-1100nm
|
320-1100nm
|
Spectral Bandwidth
|
2nm
1nm
0.5,1,2,4,5nm
|
Wavelength Accuracy
|
± 0.5nm
|
Wavelength Repeatability
|
≤0.2nm
|
Photometric Accuracy
|
± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T)
|
Photometric Repeatability
|
0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)
|
Stray Light
|
≤0.04% T @ 360nm; 220nm
|
Stability
|
± 0.001A / h @ 500nm
|
Baseline Flatness
|
± 0.002A
|
Noise
|
0.0005Abs @ 500nm
|
Display
|
480*272 65 thousand true color TFT LCD
|
Photometric Mode
|
T, A, C, E
|
Photometric Range
|
0-200% T,-0.301~3.0A
|
Detector
|
Silicon Photodiode
|
Light Source
|
Deuterium Lamp, Tungsten Lamp
|
Input
|
Membrane Keypad
|
Output
|
USB2.0*2 Print and data output USB1.0 Connect PC
|
Standard Accesseries
|
10mm glass cuvette *4 units 10mm quartz cuvette *2 units
|
10mm glass uvette *4 units
|
Power Supply
|
110V/220±10% ,60/50Hz
|
Packing Size(mm)
|
620*500*370
|
620*500*370
|
Gross Weight(kg)
|
18
|
16.5
|
Accessories

bio-equip.cn