Login    Join free Add to favorites    中文
Home >Products> Spectrum | HPLC | GC | MS >Spectrophotometers> WFX320 Flame Atomic Absorption Spectrophotometer (AAS)
WFX320 Flame Atomic Absorption Spectrophotometer (AAS)
WFX320 Flame Atomic Absorption Spectrophotometer (AAS)
Origin of place China
Model AE-WFX320
Supplier A&E Labmed
Price
Hits 914
Updated 1/12/2018
  • Product Detail
  • Company Profile

FEATURES:

High cost-effective flame AAS

Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users

Reliable integration of main unit with microprocessor

Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument.

Simple and East Operation

Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analysis.

 

SPECIFICATIONS:

Main Specification

Wavelength range

190-900nm

Wavelength accuracy

±0.5nm

Resolution

Two spectral lines of Mn at 279.5nm and

279.8nm can be separated with the spectral

bandwidth of 0.2nm and valley-peak energy

ratio less than 30%.

Baseline stability

0.005A/30min

Background correction

The D2 lamp background correction

capability at 1A is better than 30 times.  

Light Source System

2 lamps are powered simultaneously (one preheating)

Lamp current adjustment range:  0~20mA,                              

Lamp power supply

mode

Powered by 400Hz square pulse

Optical System

Monochomator

Single beam, Czerny-Turner design grating

monochromator

Grating

1800 l/mm

Focal length

277mm

Blazed Wavelength

250nm

Spectral Bandwidth

0.1nm, 0.2nm, 0.4nm, 1.2nm 4 steps

Adjustment

Manual adjustment for wavelength and slit

Flame Atomizer

Burner

10cm single slot all-titanium burner   

Spray chamber

Corrosion resistant all-plastic spray chamber.

Nebulizer

High efficiency glass nebulizer with metal

sleeve, sucking up rate: 6-7mL/min

Position adjustment

Manual adjusting mechanism for vertical,

horizontal positions and the rotation angle of

he burner

Gas line protection

Fuel gas leakage alarm

Detection and Data

Processing System

Detector

R928 Photomultiplier with high sensitivity and wide spectral range.

Electronic and

micro-computer system

Automatic adjustment of light source power.

Light energy and negative high-voltage

auto-balance

Display mode

LED display of energy and measurement

values, concentration direct reading

Read mode

Transient, time average, peak height, peak area.

Integral time is selectable in the range of 0.1-19.9s.

Scale expansion

0.1~99

Data processing mode

Automatic calculation of mean, standard

deviation and relative standard deviation.

Repeating  number is in the rang of 1-99

Measurement mode

Automatic curve fitting with 3~7 standards;

Sensitivity auto-correction

Result printing

Measurement data, working curve, signal

profile and analytical conditions can all be

printed out.

Instrument self-check

Check current status of each function key

Characteristic

Concentration and

Detection Limit

Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L,

Detection limit≤0.006mg/L;

Function Expansion

Hydride vapor generator can be connected for hydride analysis.

Dimensions and

Weight

1020 x 490 x 540 mm, 80kg unpacked

My email is  dvp@aelabcn.com , pls feel free to contact me.

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号