WFX-110B/120B/130B Flame Atomic Absorption Spectrophotometer
WFX-110B/120B/130B Flame Atomic Absorption Spectrophotometer
Origin of place China
Model WFX-110B/120B/130B
Supplier Beijing Beifen-Ruili Analytical Instrument Co. Ltd.
Price
Hits 3517
Updated 4/10/2019
  • Product Detail
  • Company Profile

Features

1 Innovated rich oxygen air-acetylene flame analysis technique(WFX-110B):

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950℃ which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis

 

2 Flame atomization system with flame emission burner

 

2.1 A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc.(WFX-110B/120B) 

 

3 Accurate fully automated control system

 

3.1 Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position

 

3.2 Automatic wavelength scanning and peak picking

 

3.3 Automatic spectral bandwidth changing

 

3.4 Automatic ignition 

 

4 Perfect safety protection measures

 

4.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

 

5 Advance and reliable electronic design

 

5.1 Adopting large-scale programmable logic array and Inter I2C bus technology

 

5.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

 

6 Easy and practical analysis software

 

6.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization

 

6.2 Automatic sample dilution, automatic calculation and analytical result automatic print out

 

Main Specification

Wavelength range

190-900nm
Wavelength accuracy  ±0.25nm
Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability 0.004A/30min
Background correction
The D2 lamp background correction capability at 1A is better than 30 times
The S-H background correction capability at 1.8A is better than 30 times.( only for WFX-110B/120B)
Light Source System Lamp turret 6-lamp turret (WFX-110B/120B), 4-lamp turret (WFX-130B); Auto-alignment, fully automated scan and peak-picking.
Lamp current adjustment

400Hz square wave pulse

Wide pulse current: 0~25mA,
Narrow pulse current: 0~10mA

Lamp power supply mode

400Hz square wave pulse;

100Hz narrow square wave pulse+400Hz wide square wave pulse (WFX-110B/120B)

Optical System Monochomator Single beam, Czerny-Turner design grating monochromator
Grating 1800 l/mm
Focal length 277mm
Blazed Wavelength 250nm
Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change
Flame Atomizer Burner 10cm single slot all-titanium burner
Spray chamber Corrosion resistant all-plastic spray chamber
Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Emission burner provided with WFX-110B/120B
Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range.
Software  Windows operating system
Analytical method Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
Repeat times Maximum 20 times of repeat measurement, automatic calculation of mean value, standdard deviation and relative standard deviation.
Multi-task Functions Sequential measurement for multi-element determination in one sample
Condition reading With model function
Result printing Measurement data and final analytical report printout, editing with Excel
Standard RS-232 serial port communication
Characteristic Concentration and Detection Limit

Normal Air-C2H2 flame

Oxygen-rich Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Ba:  Characteristic concentration ≤ 0.22mg/L
Al:   Characteristic concentration ≤ 0.4mg/L
Function Expansion
Hydride vapor generator can be connected for hydride analysis
Dimensions and weight Main unit 102×49×54cm, unpacked 80kg

 

 
 
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号