Profile
In 1931,the CIE(Commission Internationale De L'E'clalrage)setup a series of visible spectrum color space standards.The Basic CIE color space standardS iS CIE_XYZ.lt iS built on standard visual observerson the basis of ability to see,and it reflects the standardS scope of color by eye.Based On CIE_XYZ there are CIE_XvY,CIE_Lab,CIE Lch standard color space,etc.
At present,the CIE Lab color space iS the most commonly used in the industry.In ClE Lab color space,L value stands for color brightness and a value stands for the Green-0n-red value.and b value stands for the blue—on—yellow color value.If determine a value of color by only a group Lab,it will be not practical.However,we can determine the differences among them by comparing two groups of Lab values.
◆Technical Features:
⊙Easy operation make you use it easily
⊙Widely applied to quality control of plastic and printing industries’
⊙Display directly color difference by △E*ab、△L*a*b、CIE_L*a*b、CIE_L*C*h
⊙Standard deviation within△E*ab0.2(test condition:choose average values by 12pcs white tabula)
⊙It can be connected with computer to do the inspection by software with USB expansion interface.
◆Skills Indications
test accuracy |
Within 0.2 △E*a b |
Display |
△E*ab、CIE_Lab、△L,△a,△b、CIE_Lch |
Test swpe |
L:0—100 a:-128--127 b:-128--127 |
Test time |
About 3 seconds |
Test Interval |
2 seconds |
Test aperture |
¢8mm |
Automatic shutdown |
Automatic shutdown after 5 minutes waiting |
Light source |
C light source |
Sensor |
Correct sillicon photodiode carrays |
Power |
DC/5V(1.5A).2pcs 1.5V(AAA)batteries |
Size |
171*50*48.8mm |
Weight |
203.6g(Exclusive battery) |
Ope rated temperature scope |
0-40 ℃132-104'f);lower than 85% relative humidlty |
Standard accessories |
1 pc nlanual/softwbag/9V battery/5v external power supply/USB connecting cable/CD |
Application |
Measure any color Of smooth surface |
◆CIE color space coordinate chart ◆Connecting with computer to do the analysis
COLOR DIFFERENCE FORMULA
△E*ab=[(△L*)2+(△a*)2。+(△b*)2]1/2
△L*=Lsample一L*standard(lightness difference)
△a*=a*Lsample一a* standard(red/green diference)
△b*=b*Lsample—b standard。mmd(yellow/blue difference)
◆Workin~theory
Compa re the color difference between sample and the measured subject then
output CIE_Lab 3 groups data,and the 4 groups of △E,△L,△a,△b data after
comparision
△E stands for the totaI color difference.
△L+stands for partial white,△L-stands for partial black(cornpa ring with p rototype)
△a+stands for pa rtial red,△a—stands for partial green(comparing with p rototype)
△b+stands for pa rtial yellow,△b-stands for pa rtial blue(comparing with plrototype)
Color dif SCOpe |
Color dif.anylysis |
0.0 25AE |
very small or no;very perfect matching |
0.25—0.5△E |
small;acceptable matching |
0.0—1.0△E |
small to medium:acce-ptabIe in some areas |
1.0—2.0△E |
Medium:acceptable in some a reas |
2.0—4.0△E |
has dislance:acceptable in special applications |
4.0 △E |
ve ry big;not acceptable in most applications |
bio-equip.cn
Tsingtao Toky Insturments Co.,Ltd is one of hi-tech factory specialized in the production of instruments and meters,all of our Products are sold to europe, japan, usa, the middle east countries and regions.
Follow the innovation of the world, we will continue to seek progress in science and technology for development purposes, to meet customer demands for better and more cost-effective products.
In future, Toky Instruments will do everything to develop products meeting the highest technical requirements. TUOKO sincerely welcomes its friends to cooperate with us for the further achievements.
our main products:Moisture Meter,Ultrasonic Thickness Gauge,Coating thickness Meter,Surface Roughness Tester,Glossmeter,Sound Level Meter,Anemometer,Lux Meter,Tachometer,Infrared Thermometer