 Hotplate magnetic stirrer

The ES series hotplate magnetic stirrers are designed to provide users with a high quality, low cost heating/stirring system for routine applications.The low profile case construction is carefully designed to ensure that any spillage is prevented from affecting the performance of the unit. The robust cast plinth will withstand the most severe handling. Standard laboratory scaffolding is to be used in conjunction with the unit.

Key features:
  • Smart microprocessor design provides unique linear and consistent performance of heating and stirring.
  • Stirring can be controlled from 0-2000rpm, with smooth and rapid speed changes guaranteed to ensure the magnetic follower always stays under control.
  • Quiet direct drive motor / magnet system.
  • Advanced safety features and easy to clean.
  • Sealed outer shell design with long service time.
  • Compact and light weight.
 
  Technical parameters 

Type
Stirring Speed
Maximum Stirring Volume
Working Dimensions
 
Temperature Range
Temperature Stability
Surface Material
Power
Weight
ES 20A
0-2000rpm
5 (Water)L
ф120mm
Ambient~220℃
±8℃
Aluminium alloy with anticorrosive coating
450W
2Kg
ES 30A
0-2000rpm
5 (Water)L
ф120mm
Ambient~350℃
±8℃
Stainless Steel
450W
2Kg

  Lightwave heater  

Applying infrared lightwave to heating sample is a new heating concept. LabTech design and manufature the HR series lightwave heaters, which are economic units offering the excellent heating performance needed in the most demanding applications. Save lots of energy and time when compared to ordinary heating device.

 
Key features:
HR 1000
 

 

 

 

 

HR1000 Plus

  • Fast heating: 
    Temperature rising speed is 40% faster than ordinary ceramics hotplate.
  • Uniform and stable heating: 
    Heating is more uniform and stable than ordinary ceramics hotplate.
  • Energy saving: 
    40% energy saving in comparison to a conventional type heater.
  • Timing function: 
    You can set the work time for completely unattended operation.
  • Variable power: 
    Heating power is adjustable to satisfy different needs.
  • Corriosion resistant: 
    Top plate is quartz without corrosion problem.
Technical parameters 

Model Working Dimension Heating Mode Temp. Range Heating Power Material Dimension(W×L×H) Weight
HR1000 Ø150mm Infrared radiation and conduction Ambient ~ 450℃ 1000 W Quartz Glass and Stainless Steel 340×260×80mm 2.5 Kg
HR1000 Plus Ø150mm Infrared radiation and conduction Ambient ~ 450℃ 1000 W Quartz Glass and Corrosion-resistant 340×260×80mm 2.5 Kg

  Filtration System

1. Solvent Filter (All glass Holder)

 

 

Features and Use

This crystal-clear solvent filtration system is made of high-quality extra hard glass with uniform thickness. It is leak-proof and its size is in agreement with the international standard. The product can be used for sterilization at high temperature and high pressure, and is particularly suitable for filtration of HPLC mobile phase, eliminating outgas and particles and avoiding the blockage of HPLC liquid flow path.

Technical Specification and Parameter

Filter head: external diameter is slick; internal diameter is frosted.
Clamp: made of aluminum alloy, high strength, no distortion.

P/N

Funnel

Aperture of Filter

Pore Size of Filter

Material of Filter

Receiving Bottle

Suitable Membrane

LTGF001

300 ml

50 um

10 um

Pyrex glass

1 L

φ47 mm

LTGF002

500 ml

60 um

10 um

Pyrex glass

2 L

φ60 mm

LTGF003

300 ml

50 um

20 um

PTFE

1 L

φ47 mm

The Funnel, filter and receiving bottle are all with pricise ground-glass sealing surfaces. The filter is also called support screen. And the PTFE support screen is replaceable.
 

2. Manifolds Vacuum Filter

 

Multi-branch Manifold filter is designed for simultaneous filtration of several samples for time-saving operations. Because each filter holder has individual control valve, only one vacuum pump is needed either for single or multiple manifold filter operations. The use of stainless steel Multi-branch Manifold filter holder allows filtration at 180℃; and the high-quality extra hard glass with elegant workmanship can bear up to 200℃.

Components:
  • All glass funnel
  • Pyrex glass support screen
  • Stainless steel filter holder
  • Stainless steel valve or PTFE valve
  • Clamp of aluminum alloy
  • Stopper

Configurations:

  • Three branch stainless steel vacuum filter
  • Six branch stainless steel vacuum filter
Characteristics:
  • Each holder has individual control valve, resulting in flexibility in use, convenience in antisepsis, and high efficiency.
  • Test three or six samples at the same time with ease, leading to high sensitivity, low false –positive and high efficiency. 
Operation range:

Widely used in the areas of chemical analysis, biochemical-pharmaceutical sanitation, environmental analysis, water quality analysis, and food/beverage sciences.

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号