The advanced WS-GP2 Automatic Weather Station is based on the powerful GP2 Data Logger. It is an ideal solution for research and environmental monitoring applications at remote and exposed sites. The WS-GP2 provides a highly rugged and flexible system – users can select the optimal combination of sensors, logger, power and communications.

Specification
GP2 Data Logger – Brief Specs
|
Specification |
Range / Note |
Analog accuracy |
-0.17 to +2.7V |
0.005% + 115μV |
at 25°C |
±23mV |
0.022% + 12μV |
|
-0.17 to +2.7V |
0.04% + 150μV |
-20°C to +60°C |
±23mV |
0.08% + 27μV |
Accuracy other |
See detailed specification in GP2 User Manual |
Readings |
2.5 million (approximately) |
depends on program settings |
Logging frequency |
1s to > 24 hours |
|
Logging status |
Flashing LED |
|
Environmental |
-20°C to +60°C, IP65 |
|
Power |
6 AA alkaline batteries or external power 10-15V DC |
Input connections |
12 differential (or 24 single-ended) analog inputs configurable as: Voltage, Resistance (12 3-wire or 24 2-wire), Bridge (12), Potentiometer (12)
4 digital inputs as: Counters, (2 fast + 2 slow), Frequency, Digital state
|
1 Delta-T WET sensor channel
Or
1 x SDI-12 digital bus InterfaceUnlimited virtual channels |
For full GP2 specification please see the GP2 data sheet
WS-GP2 Sensors – Brief Specs
|
Specification |
Range / Note |
Wind speed AN-WD2 (combined wind sensor) |
Range |
0 to 75m.s-1 |
|
Accuracy |
± 0.1m.s-1 |
Up to 10m.s-1 |
± 1.1% of reading |
Over 10m.s-1 |
Starting threshold |
0.4m.s-1 |
-30°C to +70°C if icing minimal |
Wind direction AN-WD2 (combined wind sensor) |
Accuracy |
± 4° |
mechanical: 0 to 360°
electrical: 0 to 356°
|
Starting threshold |
0.4m.s-1 |
-30°C to +70°C (if icing minimal) |
Rainfall RG2+BP |
Sensitivity |
0.2mm per tip |
up to 360 mm.hr-1 |
Humidity RHT2nl (combined air temp sensor) |
Accuracy |
± 2% RH |
5 to 95% RH |
± 2.5% RH |
<5% and >95% RH |
Air temperature RHT2nl (combined RH sensor) |
Accuracy |
± 0.1°C |
0 to 70°C |
Solar radiation ES2 |
Absolute accuracy |
± 5% |
At 20°C (optimal conditions) |
Linearity |
± 1% |
0 to 2 kW.m-2 |
Soil temperature ST1 |
Accuracy |
± 0.2°C |
-10 to +65°C |
Mast M2-FSG |
2m mast |
With cross arm, stakes, steel guy wires, baseplate and logger canopy |
bio-equip.cn