Login    Join free Add to favorites    中文
Home >Products> Plant Physiology | Ecology >Agrology / Ecology> WS-GP2 Advanced Automatic Weather Station System
Plant Physiology | Ecology:  Plant Physiology   Agrology / Ecology  
WS-GP2 Advanced Automatic Weather Station System
Origin of place China
Model
Supplier BEIJING CHANNEL SCIENTIFIC INSURMENTCO.LTD
Price
Hits 1150
Updated 12/30/2019
  • Product Detail
  • Company Profile

The advanced WS-GP2 Automatic Weather Station is based on the powerful GP2 Data Logger. It is an ideal solution for research and environmental monitoring applications at remote and exposed sites. The WS-GP2 provides a highly rugged and flexible system – users can select the optimal combination of sensors, logger, power and communications.

Specification

GP2 Data Logger – Brief Specs

 

    Specification  Range / Note
Analog accuracy  -0.17 to +2.7V  0.005% + 115μV   at 25°C
 ±23mV  0.022% + 12μV
 
 -0.17 to +2.7V  0.04% + 150μV   -20°C to +60°C
 ±23mV  0.08% + 27μV
Accuracy other  See detailed specification in GP2 User Manual
Readings  2.5 million (approximately)  depends on program settings
Logging frequency  1s to > 24 hours  
Logging status  Flashing LED  
Environmental -20°C to +60°C, IP65  
Power 6 AA alkaline batteries or external power 10-15V DC
Input connections

12 differential (or 24 single-ended) analog inputs configurable as: Voltage, Resistance (12 3-wire or 24 2-wire), Bridge (12), Potentiometer (12)

 

 
4 digital inputs as: Counters, (2 fast + 2 slow), Frequency, Digital state

1 Delta-T WET sensor channel
Or
1 x SDI-12 digital bus InterfaceUnlimited virtual channels

For full GP2 specification please see the GP2 data sheet
 

 

 
WS-GP2 Sensors – Brief Specs

 

   Specification  Range / Note
Wind speed   AN-WD2 (combined wind sensor)
Range 0 to 75m.s-1  
Accuracy ± 0.1m.s-1 Up to 10m.s-1
± 1.1% of reading Over 10m.s-1
Starting threshold 0.4m.s-1 -30°C to +70°C if icing minimal
Wind direction   AN-WD2 (combined wind sensor)
Accuracy ± 4°

mechanical: 0 to 360°

electrical: 0 to 356°

Starting threshold 0.4m.s-1 -30°C to +70°C  (if icing minimal)
Rainfall RG2+BP
Sensitivity 0.2mm per tip up to 360 mm.hr-1
 Humidity RHT2nl  (combined air temp sensor)
Accuracy ± 2% RH 5 to 95% RH
± 2.5% RH <5% and >95% RH
Air temperature RHT2nl (combined RH sensor)
Accuracy  ± 0.1°C 0 to 70°C
Solar radiation ES2
Absolute accuracy ± 5%  At 20°C (optimal conditions)
Linearity ± 1% 0 to 2 kW.m-2
 Soil temperature ST1
Accuracy ± 0.2°C -10 to +65°C
Mast  M2-FSG
2m mast With cross arm, stakes, steel guy wires, baseplate and logger canopy
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号