The WS-GP1 Automatic Weather Station includes high grade sensors to measure rain, solar radiation, wind speed, wind direction, relative humidity and air temperature. The system comes complete with the GP1 Data Logger and a 2m tripod mast.

Specification
|
Specification |
Range / Note |
Wind speed D-034B-CA (combined wind sensor) |
Range |
0.4 to 75 m.s-1 |
(0-167 mph) |
Accuracy |
± 0.1m.s-1 |
Up to 10.1 m.s-1 |
± 1.1% of reading |
Over 10.1 m.s-1 |
Starting threshold |
0.4 m.s-1 |
-30° to +70°C (if icing minimal) |
Wind direction D-034B-CA (combined wind sensor) |
Accuracy |
±4 degrees
0.5° (resolution) |
Mechanical: 0 to 360°
Electrical: 0 to 356° |
Starting threshold |
0.4 m.s-1 |
-30° to +70°C (if icing minimal) |
Rainfall RG2+WS-CA |
Sensitivity |
0.2 mm/tip |
160 mm funnel diameter |
Humidity RHT3nl-CA (combined air temp sensor) |
Accuracy |
± 2% RH |
5 to 95% RH[1] |
± 2.5% RH |
<5%, >95% RH |
Air temperature RHT3nl-CA (combined RH sensor) |
Accuracy |
± 0.3°C |
-20 to 70°C |
Solar radiation D-PYRPA-CA |
Accuracy |
± 5% |
0 to 1.1 kW.m-2
300 to 1100 nm |
Cosine response |
± 1% at 45°
± 4% at 75° |
At zenith angle |
Data recording and power |
Logging frequency |
1 s to 24 hr |
Logging status indicated by flashing LED |
Comms |
To PC or laptop |
RS232, USB[2] or modem |
Battery life |
9 V alkaline |
190 days typical, reading every 5 minutes |
Physical |
Environmental |
IP65 sealing |
|
Temperature |
-20 to +60°C |
If icing minimal |
Cross-arm |
White-painted stainless steel |
Fits horizontal. or vertical pole (42-52 mm diameter.) |
Weight |
14.3 kg |
Complete with 2 m tripod and ground stakes |
[1] At 23°
[2] With USB to RS232 Adapter Cable type USB-RS232
bio-equip.cn