AP4 Leaf Porometer features

The AP4 Leaf Porometer measures diffusion conductance by comparing the precise rate of humidification within a small cuvette (chamber) to readings obtained with a calibration plate. The plate has 6 diffusion conductance settings whose values have been accurately determined by finite element analysis.

Quoted accuracy figures for other porometers and gas analysis systems are based on time-consuming laboratory set-up and calibrations which bear little comparison to field conditions. In contrast, the AP4 Leaf Porometer features simple direct calibration in the field against a tested physical standard.

Parameter  Reading range  Resolution [1] Accuracy [2] Test conditions [5]
Reading range
 Conductance  5.0 -1200 mmol m-2 s-1  0.1 – 10  ± 10 %  5 – 800 mmol m-2 s-1
 ± 20 %  800 – 1200 mmol m-2 s-1
 Conductance  0.25 – 30.0 mm s-1  0.01 – 0.1  ± 10%  0.25 – 20 mm s-1
 ± 20 %  20-30 mm s-1
 Resistance  0.2 – 40 s cm-1  0.01 – 0.1  ± 10 %  0.5 – 40 s cm-1
 ± 0.2 s cm-1  0.2 – 0.5 s cm-1
 RH  0 – 100%  0.1  ± 4%  
 Cup temp  -5 – +55 °C  0.1  ± 0.7 °C  0 – 50 °C
 Cup-leaf temp  -5 – +5 °C  0.1  ± 0.2 °C  0 – 50 °C
 PAR flux [3]  0 – 2500 µmol m-2 s-1  10  ± 15%  
 Pressure [4]  600 – 1200 hPa, settable in steps of 5 hPa  
 RH cycle level  20 – 80 %RH, settable in steps of 5%  

[1] Resolution varies with the magnitude of the value obtained.  The range shown corresponds to the reading range.  In relative terms, the resolution is better than 2%, but at least the smallest amount shown.
[2] The stated accuracy applies over the range of the calibration plate and for optimum cup conditions, i.e. from +10 to -5 °C difference between actual cup temp. and that existing at calibration, and for +2.5 to -2.5 °C difference between leaf and cup temperatures.
[3] Spectral and cosine responses are approximate only.
[4] Ambient pressure may be read from a Wristwatch Barometer type PBR1. 
[5] Cycling at extreme combinations of temperature, conductance and RH level may not always be possible.

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号