Login    Join free Add to favorites    中文
Home >Products> Plant Physiology | Ecology >Plant Physiology> Yaxin-1101s Photosynthesis Meter
Plant Physiology | Ecology:  Plant Physiology   Agrology / Ecology  
Yaxin-1101s Photosynthesis Meter
Yaxin-1101s Photosynthesis Meter
Origin of place China
Model Yaxin-1101s
Supplier Beijing Yaxinliyi Science and Technology Co., Ltd.
Price
Hits 520
Updated 9/19/2024
  • Product Detail
  • Company Profile

Yaxin-1101s Photosynthesis Meter

Yaxin-1101s Pn Meter is specially designed for the teaching of plant physiology experiment in university. The instrument uses gas exchange method to measure leaf photosynthesis. The difference value of CO2 concentration which leaf photosynthesis in chamber is measured, and then the photosynthetic rate of leaves is calculated.
I. Instrument Functions

1. Measurement function: Gas CO2 concentration, humidity, temperature, leaf surface temperature, light intensity (PAR), gas flow rate

2. Calculation function: Photosynthetic (respiration) rate, transpiration rate, intercellular CO2 concentration and stomatal conductance

3. Display function: CO2 reference value/measured value; RH (relative humidity) reference value/measured value; Air temperature; Leaf surface temperature; Leaf area, flow rate and atmospheric pressure; Light intensity (PAR)

4. Software functions: Synchronous projection function; Manually controllable light source; Transmission software is free of installation; Support firmware upgrade through USB port; There are two measurement system: open system and closed system. Open system is preferred

5. Power supply function: Rechargeable battery; Low voltage alarm

Ⅱ. Technical Parameters

1. CO2 sensor

Type: Non-diffusion infrared analyzer; Range: 0.0~2000.0 ppm; Resolution: 1.0 ppm; Accuracy: 3.0 ppm; Response time: 5s

2. Optical quantum sensor

Type: silicon photocell with correction filter; Range: 0.0~2500.0 μmol/m2 s; Spectrum: 400.0~700.0 nm, visible light range; Resolution: 1 μmol/m2 s; Error: 2%

3. Leaf temperature sensor

Type: T thermocouple; Range: 0.0 ~ 50.0℃; Resolution: 0.1℃; Error: 0.3℃; Response time: 1s

4. Air temperature sensor

Type: thermistor; Range: 0.0 ~ 50.0℃; Resolution: 0.1℃; Error: 0.3℃

5. Humidity sensor

Type: humidity sensitive capacitor; Range: 0 ~ 100% RH; Resolution: 0.10%; Error: ±1.5 %RH;

Response time: 8s

6. Flowmeter

Type: Microelectronic flowmeter; Range: 0.0 ~ 1.0 L/min; Resolution: 0.01 l/min; Error: 1% reading

7. Light control module

Type: LED white light source; Range: 0.0~3500.0 μmol /m2 s can be set; Luminous area: 3.0× 7.5 cm; Light intensity control, set by software, automatic control

8. Power supply system

Battery: 7.2 V 10.0 AH rechargeable lithium battery, with battery life of 8~15h; Power adapter: 8.4V 2.0A lithium battery power adapter

9. Host

Display: 5-inch color touch screen; Storage: 9999 sets of data can be stored; Transmission: USB port; Size: 24.5×15.0×20.0 cm; Weight: about 3.3kg.

10. working environment

Temperature: -20.0 ~ 50.0℃; humidity: 0 ~ 100% RH, no condensation

11. Leaf chamber

Leaf chamber: (65×10mm)

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号