Overview:

    

      Winner2000  is an entry level and high efficient-cost with stable good performance model, working with principle of MIE Scattering to precisely determine the particle size distribution from 

0.1 to 300 micrometer. It enables you understand materials well, such as painting,dyes, minerals power, Photosensitive material,Medicine and Metal oxide etc. Our Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research and product development, manage and control manufacturing quality, and optimize output, It’s our classical model, widely used in universities research and company lab research.

 

 

 

 

 

 

 

1,Main Specification:

 

Model Name

Winner2000E

Standard

ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009

Principle

MIE scattering principle

Measuring Range

0.1-300μm

Channels Number

96 PCS

Accuracy   

<1%   (National Standard Sample D50 )

Repeatability

<1%   (National Standard Sample D50 )

Light source

High performance He-Ne Laser (λ= 632.8nm,  P>2MW)

Lifetime>25000hour

 

Dispersion

 Method

Ultrasonic

Frequency:40KHz   Power:35W,   Time: ≥1S

Stir

Revolutions Speed: 0-300RPM (Adjustable)

Circulate

Rated Flow:8L/min    Rated Power:10W

Sample Pool

Volume:350mL

 

Sample Pool

Available)

Operation Mode

Digital display control

Output parameter

D10,D50,D90,D100,S/V referent parameters

Optical Calibration System

Manual

Test Speed

<2mins per time

Outer dimension

L66*W32*H40cm

Net Weight

32Kg

Warranty

2 years

 

2,Main Features:

1)Working principle: Mie Scattering Theory 

 

2)High efficient-cost model, semi automatic button control.

 

3) Wet Sample Preparation and Dispersion system

Full built in dispersion system, including manual water supply, Key operation control circulation, ultrasonic dispersion,draining water and cleaning pipe, make sure that sample can be dispersed

sufficiently, prevent large particle sediment in the pipe, offer stable and reliable test results.

 

 

 

 

4)Stable optical path system

Winner Patented Technology, Unique designed converging light Fourier transform light path, efficiently improve resolution ratio of sub-micron particles.

 

5)High sensitive Detectors:

Main& auxiliary detectors are fan-shaped, It can receive all scattered light signals from sub-micron to millimeter accurately, guarantee the effective capture of the scattered signal,ensure the good accuracy and repeatability.

 

  1. Self-developed software System: Unconstrained free fitting patent technology, make particle analysis not restricted by any function, truly reflect particles 

distribution, ensure the good accuracy. Friendly human interface, easy and simple to learn. 

 

 

 

3, Software Function:

 

1, Analysis Mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.

 

2,Statistic Method

Volume Distribution, Quantity Distribution

 

3,Statistic Comparison

Statistic Several Testing Results to compare and analyze

Get difference by compare test result of different batches of samples, samples  before and after processing, and different time.

Have great practical significance to industrial raw materials quality control

 

4,User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries.

 

5,Test Report

Word, Excel,Photo( Bmp), Text etc.

 

6,Multiple language Support

Chinese&English (Others are available)

 

7,Intelligent Operation Mode

Automatically control water inflow, dispersion,test and analysis.

Better Repeatability after remove human-factor

 

 

 

4. Laser Particle Size Analyzer Application Field:

  

1.Non-metallic powders such as calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, silica powder, tourmaline, mica, barite, plaster, bentonite, diamond, quartz, diatomite, feldspar, calamite,clay, garnet, vermiculite, Titanium white power, etc.


2. Metallic powder such as aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, other rare metal power and varied alloy powder, etc.


3. Pharmaceutical, agricultural pesticide, grinding particle, foodstuff, scientific research, teaching, cement, ceramic, glass, chemical industry, military industry, soil, toner,pigment, oil exploration, geological analysis, river silt and electronic particle, etc.

 

 

5. Winner2000E Laser Particle Size Analyzer Patents Technology:

 

l Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,

l MIE scattering principle application patent is protected by patent No.- ZL 2013 2 0812021.4.

l Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2.

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号