The DC series thermostat water bath provides a field source with controlled heating and cooling, uniform and constant temperature for users to conduct constant temperature experiments or tests on experimental samples or produced products, and can also be used as direct heating or cooling and auxiliary heating or cooling. source of heat or cold.
Model
|
Temp. Range(℃)
|
Temp. fluctuation(℃)
|
Resolution(℃)
|
Tank volume(mm3)
|
Work opening(mm2)
|
Depth(mm)
|
Flow(L/min)
|
Dimensions (mm)
W*D*H
|
DC-0506
|
-5~100
|
±0.05
|
0.01
|
250×200×150
|
180×160
|
150
|
6
|
320x370x655
|
DC-1006
|
-10~100
|
±0.05
|
0.01
|
250×200×150
|
180×160
|
150
|
6
|
320x370x655
|
DC-2006
|
-20~100
|
±0.05
|
0.01
|
250×200×150
|
180×160
|
150
|
6
|
320x370x655
|
DC-3006
|
-30~100
|
±0.05
|
0.01
|
250×200×150
|
180×160
|
150
|
6
|
320x370x655
|
DC-4006
|
﹣40~100
|
±0.05
|
0.01
|
250×200×150
|
180×160
|
150
|
6
|
320x370x765
|
DC-4506
|
﹣45~100
|
±0.05
|
0.01
|
250×200×150
|
180×160
|
150
|
6
|
320x370x910
|
DC-0510
|
﹣5~100
|
±0.05
|
0.01
|
250×200×200
|
180×160
|
200
|
6
|
320x370x765
|
DC-1010
|
﹣10~100
|
±0.05
|
0.01
|
250×200×200
|
180×160
|
200
|
6
|
320x370x765
|
DC-2010
|
﹣20~100
|
±0.05
|
0.01
|
250×200×200
|
180×160
|
200
|
6
|
320x370x765
|
DC-3010
|
﹣30~100
|
±0.05
|
0.01
|
250×200×200
|
180×160
|
200
|
6
|
320x370x765
|
DC-4010
|
﹣40~100
|
±0.05
|
0.01
|
250×200×200
|
180×160
|
200
|
6
|
400x450x910
|
DC-4010A
|
﹣40~100
|
±0.05
|
0.01
|
310×200×150
|
180×160
|
150
|
6
|
400x450x910
|
DC-0515
|
﹣5~100
|
±0.05
|
0.01
|
300×250×200
|
235×160
|
200
|
6
|
320x370x765
|
DC-1015
|
﹣10~100
|
±0.05
|
0.01
|
300x250x200
|
235×160
|
200
|
6
|
320x370x765
|
DC-2015
|
﹣20~100
|
±0.05
|
0.01
|
300×250×200
|
235×160
|
200
|
6
|
320x370x765
|
DC-3015
|
﹣30~100
|
±0.05
|
0.01
|
300×250×200
|
235×160
|
200
|
6
|
400x450x910
|
DC-4015
|
﹣40~100
|
±0.05
|
0.01
|
300×250×200
|
235×160
|
200
|
6
|
400x450x910
|
DC-0520
|
﹣5~100
|
±0.05
|
0.01
|
280×250×300
|
235×160
|
300
|
6
|
400x450x910
|
DC-1020
|
﹣10~100
|
±0.05
|
0.01
|
280×250×300
|
235×160
|
300
|
6
|
400x450x910
|
DC-2020
|
﹣20~100
|
±0.05
|
0.01
|
280×250×300
|
235×160
|
300
|
6
|
400x450x910
|
DC-3020
|
﹣30~100
|
±0.05
|
0.01
|
280×250×300
|
235×160
|
300
|
6
|
400x450x910
|
DC-4020
|
﹣40~100
|
±0.05
|
0.01
|
280×250×300
|
235×160
|
300
|
6
|
540x650x1090
|
DC-0530
|
﹣5~100
|
±0.05
|
0.01
|
420×330×230
|
310×280
|
230
|
13
|
405x535x935
|
DC-1030
|
﹣10~100
|
±0.05
|
0.01
|
420×330×230
|
310×280
|
230
|
13
|
405x535x935
|
DC-2030
|
﹣20~100
|
±0.05
|
0.01
|
420×330×230
|
310×280
|
230
|
13
|
405x535x935
|
DC-3030
|
﹣30~100
|
±0.05
|
0.01
|
420×330×230
|
310×280
|
230
|
13
|
405x535x935
|
DC-4030
|
﹣40~100
|
±0.05
|
0.01
|
420×330×230
|
310×280
|
230
|
13
|
540x650x1090
|
bio-equip.cn
Shanghai Xiwen Biotech Co., Ltd. mainly engaged infreeze dryer, spray dryer, ultrasonic cell disrupter and other experimental apparatus.
We had professional the temperature technicians and advanced production equipment, improve the production process, established a complete quality management system, received the ISO9001:2000 quality management certificate; ensure product quality, to achieve safety in production.
Through all our staffs joint efforts ,our main products are exported to Southeast Asia, The Middle East, Africa, Europe ,and other countries and regions, now we are looking forward to cooperating with you and create a new future together.