Login    Join free Add to favorites    中文
Home >Products> Cryostat | Freezers | Thermostat >Water Baths & Circulators> Constant Low Temperature Bath
Constant Low Temperature Bath
Constant Low Temperature Bath
Origin of place China
Model N1 -2RC
Supplier Hangzhou Bioer Technology Co.,Ltd
Price
Hits 2625
Updated 3/23/2020
  • Product Detail
  • Company Profile
·Introduction
The constant low temperature bath is comprised of a refrigeration compressor system and a high precision thermostat which combines the microprocessor and the PID control techniques. The constant low temperature bath is widely used in industries such as petroleum, chemical, medicine, biochemistry, metrology and other light industries and scientific research etc.

·Features
Control panel
Digital display, easy setting and operation, adjustable temperature, alarm signal display
Advanced Thermostatic Controller
High temperature control accuracy of ±0.02℃
Wide temperature control range; temperature can be controlled and set at will in the range of -10℃.-95℃.
Environmentally friendly compressor refrigeration system.
The compressor contains no CFC`s of HCFC`s; continuous operation in the range of –10℃-45℃, high cooling rate, high cooling power at low temperature, automatic switching on or off of the compressor.

Circulation System
The bath is fitted with a powerful jet-pump for agitating and has joints connected with the external circulation system.

Safety features
Low liquid level protection
If the water level is too low the heating pipe will shut off and the alarm light will illuminate.

Temperature out of control
If the temperature exceeds the preset level by 2℃ during the thermostatic process the heating pipe will shut off and the alarm light will illuminate.

Protection of compressor
(In the case of high working temperatures) If the temperature inside the bath exceeds 45℃ the alarm light will illuminate and the compressor will be disabled to protect the refrigeration system, thus more reliable operation is assured.

Over current protection
If the electrical current is exceeded during the course of operation the internal fuse will blow thereby protecting the apparatus and the operator.

Model Parameter N1 - 2RC
Temp. Control Range -10 ~ 95 )℃
Temp. Control Accuracy ± 0.05 ℃
Heater 1000 W
Nominal capacity of compressor 125 W
Cryogen R134a
Heating time < 80 min (From room temperature20 ℃ to 95 ℃ )
Cooling time < 150 min (From room temperature 20 ℃ to -10 ℃ )
Input A.C.Voltage AC220 ± 22V 50 ± 1Hz
Input power 1500 W
Insulation resistor ≥ 1.5 M W
Dielectric intensity Tested by AC Voltage of 50Hz,sine wave,1500V for 1minute,no flashover detected.
Internal dimension (mm) 130 × 95 × 170 ( L × W ×H )
Bath liner dimension (mm) 260×160×170 ( L × W × H )
Dimension (mm) 420×234×655 ( L × W × H )
External circulation joint dimension The jet circumfluence hole diameter:Ф10 ㎜
Net weight 25 Kg

 

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号