Login    Join free Add to favorites    中文
Home >Products> Cryostat | Freezers | Thermostat >Low Temperature Freezers> Freezer
Freezer
Freezer
Origin of place China
Model LT-UTF160W, LT-UTF380W,LT-UTF500W
Supplier LEAD-TECH (Shanghai) Scientific Instrument Co., Ltd
Price
Hits 2172
Updated 4/21/2025
  • Product Detail
  • Company Profile
Application:

    The cryogenic refrigerator is often used to keep the virus, germina, red blood cells, white blood cells, skin, bone marrow, bacteria, semen, biological products, ocean products, electronic components and special materials in low temperature tests. Customers are mainly are blood banks, hospitals, epidemic prevention stations, research institutes, electronics and chemical laboratories, biomedicine, ocean fishing, special materials experiments, military enterprises, disease control centers, etc.

1.User-friendly design:

LCD displays the content necessary for experiments including device parameters, operation process and alarm information.

Design of internal and external pressure of balance box: through composite box door design concept, effectively control the pressure difference between inside and outside the door of control box, and provide convenience for the user to open and close the box door during operation of the equipment.

Remote equipment control design: user-friendly remote control equipment, the equipment supplied with short-message control and alarm functions and mobile remote monitoring functions.

2.Safety performance:

Multiple safety sound and light warning system: by using the sound and light warning means, provide multi-parameter change warnings in terms of high and low temperature limits of box, high and low pressure limits, condenser radiation difference, and ambient temperature exceed the standard.

3.Performance description:

Vip vacuum thermal insulation technology: the high-density foam insulation layer with vacuum insulation panel improves the insulation effect effectively, reduces the thickness of the insulation layer significantly, and increases the volume of product, with small size and big capacity.

Optimized cascade refrigeration technology: smaller power, greater cooling capacity, smoother operation, and longer service life of the compressor;

Condenser fan intelligent system: intelligent fan control switch, reduction of energy consumption, effective protection of compressor.

Oil return and air return control system: ensures smooth and effective operation of the compressor, maintains the limit temperature of equipment at below 90 degrees, and ensures the service life of the compressor.

Cooling system lubrication technology: using the imported ultra-low temperature lubricant, adding a special chemical solution to the lubricating system, ensuring smooth flow of refrigerant in the capillary, and effectively preventing the lubricant from generation of oil wax in the evaporator as a result of low temperature.

Maintenance cost control: using two conventional single-use environment-friendly refrigerants, achieve low temperatures by optimizing the cascade system, avoiding the technical barriers arising from the use of mixed refrigerant, and enabling any failure of the system to be solved easily at low cost that occurs after long term use.
4.Parameters:
Model
LT-UTF390y
LT-UTF490Y
LT-UTF600Y
Temperature
Temperature range
-10℃~-86℃
Ambient temperature
10℃~32℃
Temperature Accuracy
0.1℃
Electrical indicator
Supply voltage
AC 220V 50Hz
Input power
1200W
1200W
1500W
Specifications
External dimensions (mm)
850×825×1770
850×825×2025
1000×825×2025
Liner size (mm)
650×560×1050
670×560×1305
820×560×1305
Volume
390L
490L
600L
 
Model
LT-UTF160W
LT-UTF380W
LT-UTF500W
Temperature
Temperature range
-10℃~-86℃
Ambient temperature
10℃~32℃
Temperature resolution
0.1℃
Electrical indicator
Supply voltage
AC 220V 50Hz
Input power
700W
1200W
1200W
Specifications
External dimensions (mm)
910×750×1050
1600×830×1050
1880×830×1050
Liner size (mm)
730×490×430
970×580×675
1280×580×675
Volume
160L
380L
500L
Note: All technical data are measured on standard equipment at an ambient temperature of 25℃, relative humidity of 70% and voltage fluctuation of ±10%, and the door opening temperature and humidity are based on the recovery of 98% of the original state. The Company reserves the right to change technical specifications.
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号