    FEATURES:

     

    Innovated Rich oxygen air-acetylene flame analysis technique

    The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc.  Flame temperature is continuously adjustable between 2300-2950℃, which makes it possible to choose the best atomization temperature for different elements.  It features easy operation, low analysis cost and wide flame AAS analytical range.  Rich oxygen flame is will not pollute the environment and is not harmful to human bodies.  It’s a break-through in flame AAS analysis.

     

    Integrated flame/graphite furnace atomization system, changeable with flame emission burner

    • Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor.
    • A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc.

     

    Accurate fully automated control system

    • Automatic 6-lamp turret, automatic adjustment of lamp current and optimization of light beam position.
    • Automatic wavelength scanning and peak picking
    • Automatic spectral bandwidth changing
    • Automatic changeover between flame and graphite furnace operation,  automatic optimization of position parameters, automatic ignition and automatic gas flow setting

     

    Reliable fully automatic graphite furnace analysis

    • Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity.  The temperature control accuracy is less than 1%.
    • Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact.
    • Multi-function auto sampler features automatic standard sample preparation, automatic correction of sampling probe depth, automatic tracing and correction of liquid surface height in the sample vessel, with the sampling accuracy of 1% and reproducibility of 0.3%, realizing fully automation of graphite furnace analysis.

     

    Perfect safety protection measures

    • Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system;
    • Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling water supply and over-heating in graphite furnace system.

     

    Advanced and reliable electronic design

    • Adopting large-scale programmable logic array and Inter I2C bus technology
    • European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.

     

    Easy and practical analysis software

    • Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
    • Automatic sample dilution, automatic curve fitting, automatic sensitivity correction.
    • Automatic calculation of sample concentration (content), mean value, standard deviation and relative standard deviation calculation.
    • Multi-elements determination in sequence to the same sample.
    • Measured data and final results can be printed out and edited in Excel format.

     

    Comparison

    Characteristic Mass of Some Elements using rich oxygen air-C2H2 flame and other flame methods

    Unit: ug/ml

    Element

    Wavelength (nm)

    Rich oxygen air-C2H2 flame

    N2O-C2H2 flame

    Air-C2H2 flame

    Ca

    422.7

    0.009

    0.05

    0.07

    Yb

    378.8

    0.037

    0.08

    7.6

    Eu

    459.4

    0.137

    0.3

    3.0

    Al

    309.3

    0.4

    0.7

     

    Sr

    460.7

    0.016

    0.1

    0.15

    Ba

    553.5

    0.1

    0.4

    10.0

    Mo

    313.3

    0.15

    0.4

    0.8

    W

    255.1

    3.2

    5.0

     

    Ga

    287.4

    0.4

    1.0

    1.3

    Sm

    429.7

    2.92

    8.5

     

    La

    550.1

    37.2

    35.0

     

    Sn

    224.6

    0.8

    3.0

    50

     

     

    SPECIFICATIONS:

    Main Specification

    Wavelength range

    190-900nm

    Wavelength accuracy

    Better than ±0.25nm

    Resolution

    Two spectral lines of Mn at 279.5nm and 279.8nm

    can be separated with the spectral bandwidth

    of 0.2nm and valley-peak energy ratio less than

    30%.

    Baseline stability

    0.004A/30min

    Background correction

    The D2 lamp background correction capability

    at 1A is better than 30 times.  

    The S-H background correction capability at

    1.8A is better than 30 times.

    Light Source System

    Lamp turret

    Motorized 6-lamp turret (Two high performance

    HCLs can be mounted on the turret to increase

    the sensitivity in flame analysis.)

    Lamp current adjustment

    Wide pulse current: 0~25mA,              Narrow pulse current: 0~10mA.                 

    Lamp power supply

    mode

    400Hz square wave pulse;

    100Hz narrow square wave pulse + 400Hz wide

    square pulse wave.

    Optical System

    Monochomator

    Single beam, Czerny-Turner design grating

    monochromator

    Grating

    1800 l/mm

    Focal length

    277mm

    Blazed Wavelength

    250nm

    Spectral Bandwidth

    0.1nm, 0.2nm, 0.4nm, 1.2nm, auto switch over

    Flame Atomizer

    Burner

    10cm single slot all-titanium burner   

    Spray chamber

    Corrosion resistant all-plastic spray chamber.

    Nebulizer

    High efficiency glass nebulizer with metal sleeve,

    sucking up rate: 6-7mL/min

    Emission burner provided

    Graphite Furnace

    Temperature range

    Room temperature~3000ºC

    Heating rate

       2000℃/s

    Graphite tube dimensions

    28mm (L) x 8mm (OD)

    Characteristic mass

    Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g

    Precision

    Cd≤3%, Cu≤3%, Mo≤4%

    Detection and Data

    Processing System

    Detector

    R928 photomultiplier with high sensitivity and

    wide spectral range.

    Software

    Under Windows operating system

    Analytical method

    Working curve auto-fitting; standard addition

    method; automatic sensitivity correction;

    automatic calculation of concentration and

    content.

    Repeat times

    1~99 times, automatic calculation of mean

    value, standard deviation and relative standard

    deviation.

    Multi-task Functions

    Sequential determination of multi-elements in

    the same sample.

    Condition reading

    With model function

    Result printing

    Measurement data and final analytical report

    printout, editing with Excel.

    Standard RS-232 serial port communication

    Graphite Furnace Autosampler

    Sample tray

    capacity

    55 sample vessels and 5 reagent vessels

    Vessel material

    Polypropylene

    Vessel volume

    3ml for sample vessel, 20ml for reagent vessel

    Minimum sampling

    volume

    1μl

    Repeatable sampling times

    1~99 times

    Sampling system

    Accurate dual pump system, with 100μl and 1ml

    injectors.

    Characteristic Concentration and

    Detection Limit

    Air-C2H2 flame

    Rich oxygen Air-C2H2 flame

    Cu: Characteristic concentration ≤ 0.025 mg/L, Detection limit≤0.006mg/L;

    Ba: Characteristic concentration ≤ 0.22mg/L

    Al: Characteristic concentration ≤ 0.4mg/L

    Function Expansion

    Hydride vapor generator can be connected for hydride analysis.

    Dimensions and

    Weight

    Main unit

    107×49×58cm, 140kg

    Graphite furnace

    42×42×46cm, 65kg

    Autosampler

    40×29×29cm, 15kg

     

    Pls feel free to contact me via email:  dvp@aelabcn.com

     

     

     

    bio-equip.cn
    A&E Labmed Co., Ltd have many years of manufacturing and selling wide range of scientific and laboratory instruments. Our products mainly include: UV VIS Spectrophotometer, Visible Spectrophotometer, PCR Cycler, Stirrer Hotplate, Shaker, Rocker, Block Heater, Mixer, PH/Conductivity/TDS/Salinity/Dissolved Oxygen/Free Chlorine Meter, Halogen Moisture Analyzer, Ultrasonic Cleaner and Microscope, etc.
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.