Home >Products> Reagents >ELISA / Diagnostic Kits> REAGEN Microplate reader
Reagents:  Molecular Biology   Biochemistry   Cell Biology   ELISA / Diagnostic Kits   Antibody   Serum/Medium   Other Reagents  
REAGEN Microplate reader
REAGEN Microplate reader
Place of Origin:
United States
Brand:
REAGEN LLC
Model:
RNE90002
Supplier:
REAGEN
Price:
reagenllc@gmail.com
Hits:
474 
Updated:
4/27/2018
  • Product Detail
  • Company Profile

    Basic parameters of instrument

    Weight:

    8.1kg

    Overall dimensions:

    430mm(L)×335mm(W)×175mm(H)

    Power:

    a.c.110V~220V,50-60Hz

    Fuses:

    T2AL250V

    Work Environment:

    temperature 10℃-30℃;Humidity ≤70%

    Store Environment:

    -20℃-55℃;Humidity ≤93%

    Standard Wavelength:

    405,450,492,630nm,Ten optical fibers can be configured within 400 to 800 at a time;

    Instrument sensitivity:            

    no less than 0.01L/mg.

    Instrument channel difference:

    less than 0.01A.

    Range of operating wavelength:

    400-800nm;

     

    Detection range:

    0.000-4.000A;

    Resolution ratio:

    0.001A;

    Plate reading velocity:

    5s of single waveform, 10s of dual wavelength;

    Warm up time:

    10 minute

    Interface:

    RS-232C serial interface, USB interface

    Display:

    5.7″LCD display(320×240 discernibility,256 gray scale)

    Input:

    Touch panel and pen, 

    Technical Specifications

    1) Wavelength characteristics: requirements on accurate wavelength and half wave width of optical fibers for instrument see the table below.

    Unit: nm

    Accurate wavelength

    Half wave width

    ±3.0

    ≤12

    2) Accurate absorbance and linear error: measurement accuracy and linear error of instrument shall comply with the provisions as described in the table below:

    Absorbance range

    Accuracy

    Linear error

    0.000-2.000

    ±0.01

    ±1.0%

    >2.000-3.000

    ±0.05

    ±2.0%

    >3.000-4.000

    ±0.15

    ±5.0%

    3) Repeatability of measurement of instrument: no greater than 0.5%.

    4) Instrument stability:

    a) Absorbance varies shall be no greater than ±0.005A within 10min due to drifting.

    b) If the power supply voltage of 220V varies by ±10%, the resulting variation of absorbance is no greater than ±0.005A.

    Contact: reagenllc@gmail.com

    bio-equip.cn
    REAGEN LLC is a high-tech bio-medical enterprise located,We focus on designing and producing all kinds of ELISA kits including:
    clinical disease detecting kits
    food & feed safety test kits
    animal epidemic virus detecting kits
    kits for research
    microplate readers & washers
    other related instruments and equipment
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.