Uses:
721/722 Series visible Spectrophotometer widely used in the factories, Mine, Health, School, Environmental protection, scientific research and Laboratories. Our aim is to provide our customers the precision analysis instruments.
721Characteristics:
1. Use the new model rays design and the new model 1200/mm raster display make sure the low stray light and good monochromatic light.
2. Adopting the SCM, adjust the 0%T and 100%T so easy.
3. Two kinds measure method, T and A make the operation more easy.
4. 31/2LCD screen, big sample chamber can expand the apparatus function.
5. 721-100 model with 100mm cell rack, more suitable for water analysis and sample content analysis in Water works and generating station.
722Characteristics:
1. Use the new model rays design and the new model 1200/mm raster display make sure the low stray light and good monochromatic light.
2. Adopting the SCM, adjust the 0%T and 100%T so easy.
3. Four kinds measure method, T , A, C, F, make the operation more easy.
4. 31/2LCD screen, big sample chamber can expand the apparatus function.
5. Slope(F)measure method no need do the standard sample for each measure.
6. Φ8-22mm cell rack(single chamber)
7. 722-100 model with 100mm cell rack, more suitable for water analysis and sample content analysis in Water works and generating station.
8. Can choose the printer store the measure data (need choose the micro- stylus printer)
9. RS-232 connects with computer. (Need choose the accessories software)
Optional Accessories:
1. Electronic homothermal cell rack
2. Water cycle electronic homothermal cell rack
3. 5-100mm Manual Optical Distance several rows cell racks
4. 1-4mm micro-cell rack (single chamber)
5. 100-200ml super micro-cell rack (Single chamber)
6. Φ8-22mm cell rack(single chamber)
7. AC-230 model intelligent Temperature/sampling controller
8. AC-220 model Intelligent Temperature controller
9. AC-210 model intelligent temperature controller
10. All kinds of cell racks
Main Technical Parameters:
Model
721
721-100
721
721-100
Wavelength Range
325-1050nm
325-1050nm
325-1050nm
325-1050nm
Wavelength Accuracy
±2nm
±2nm
±2nm
±2nm
Wavelength reproducibility
1nm
1nm
1nm
1nm
Spectral Bandwidth
4nm
4nm
4nm
4nm
Photometric accuracy
≤±0.6%T
≤±0.6%T
≤±0.6%T
≤±0.6%T
Photometric reproducibility
0.3%T
0.3%T
0.3%T
0.3%T
Stray light
<0.3%T
<0.3%T
<0.3%T
<0.3%T
Display model
31/2LCD
31/2LCD
31/2LCD
31/2LCD
Operation Mode
Manual
Manual
Manual
Manual
Microsoft
NO
NO
NO
NO
Stability
0.004A/H(500nm, warm-up 1Hour)
0.004A/H(500nm, warm-up 1Hour)
Optical Distance
50mm
100mm
50mm
100mm
Cuvette Frame
50mm
50mm and 100mm
50mm
50mm and 100mm
Note
No
Optional Micro- micro- stylus printer
bio-equip.cn