During scientific experiments, some substances are extremely easy to be oxidated and deliquesced, which makes the chemical reaction of such substance and preprocessing of samples extremely difficult,affecting the experiment procedure and test results. The vacuum glove case (also known as vacuum inert gas operating case) has effectively solved this problem. The equipment can ensure safe import and export of experiment samples, while smoothly operated, reacted and tested under the status of water free and oxygen free, which ensures normal execution of scientific experiments. This product is an ideal facility for colleges, institutions and enterprise laboratories. It can also be applied to such departments as Biochemistry, Metallurgy, Electronics, Chemical Engineering, Geology and Medicine etc.
CSX-1Vacuum glove box:
Box Material: SUS304 stainless steel, thickness: 6mm
Vacuum degree of the transition chamber:-0.1MPa
Vacuum degree of the box:-0.1MPa
The transition chamber size (unit:mm):Φ220×250
Box size:(unit: mm):600×500×650
Holding pressure time: more than 20 hours
Glove-mouth diameter: Φ145mm
Observation window: Customized thicken tempered glass
Lighting system: with a removable position pole at the top inside the box
Used gas: argon, helium, nitrogen (purity: more than 99.95% )
Heater, temperature controller and other equipments can also be installed as needed
CSX-2Vacuum glove box:
Box Material: SUS304 stainless steel, thickness: 6mm
Vacuum degree of the transition chamber:-0.1MPa
Vacuum degree of the box:-0.1MPa
The transition chamber size (unit:mm):Φ280×350
Box size:(unit: mm):800×650×700
Holding pressure time: more than 20 hours
Glove-mouth diameter: Φ145mm
Observation window: Customized thicken tempered glass
Lighting system: with a removable position pole at the top inside the box
Used gas: argon, helium, nitrogen (purity: more than 99.95% )
Heater, temperature controller and other equipments can also be installed as needed
CSX-3Vacuum glove box:
Box Material: SUS304 stainless steel, thickness: 6mm
Vacuum degree of the transition chamber:-0.1MPa
Vacuum degree of the box:-0.1MPa
The transition chamber size (unit:mm):Φ340×400
Box size:(unit: mm):1200×700×1120
Holding pressure time: more than 20 hours
Glove-mouth diameter: Φ145mm
Observation window: Customized thicken tempered glass
Lighting system: with a removable position pole at the top inside the box
Used gas: argon, helium, nitrogen (purity: more than 99.95% )
Heater, temperature controller and other equipments can also be installed as needed
bio-equip.cn